Your browser doesn't support javascript.
loading
Is ultrasound-guided fine-needle aspiration cytology of adequate value in detecting breast cancer patients with three or more positive axillary lymph nodes?
Kramer, G M; Leenders, M W H; Schijf, L J; Go, H L S; van der Ploeg, T; van den Tol, M P; Schreurs, W H.
Affiliation
  • Kramer GM; Department of Surgery, Noordwest Clinics Alkmaar, Wilhelminalaan 12, 1815JD, Alkmaar, The Netherlands. gaellekramer@gmail.com.
  • Leenders MW; Department of Surgery, Noordwest Clinics Alkmaar, Wilhelminalaan 12, 1815JD, Alkmaar, The Netherlands.
  • Schijf LJ; Department of Radiology, Noordwest Clinics Alkmaar, Wilhelminalaan 12, 1815JD, Alkmaar, The Netherlands.
  • Go HL; Department of Radiology, Noordwest Clinics Alkmaar, Wilhelminalaan 12, 1815JD, Alkmaar, The Netherlands.
  • van der Ploeg T; Department of Statistics, Noordwest Clinics Alkmaar, Wilhelminalaan 12, 1815JD, Alkmaar, The Netherlands.
  • van den Tol MP; Department of Surgery, VU Medical Centre, De Boelelaan 1117, 1081HV, Amsterdam, The Netherlands.
  • Schreurs WH; Department of Surgery, Noordwest Clinics Alkmaar, Wilhelminalaan 12, 1815JD, Alkmaar, The Netherlands.
Breast Cancer Res Treat ; 156(2): 271-8, 2016 Apr.
Article in En | MEDLINE | ID: mdl-26995283
ABSTRACT
This study evaluated the accuracy of ultrasound-guided fine-needle aspiration cytology of the sonographically most suspicious axillary lymph node (US/FNAC) to select early breast cancer patients with three or more tumour-positive axillary lymph nodes. Between 2004 and 2014, a total of 2130 patients with histologically proven early breast cancer were evaluated and treated in the Noordwest Clinics Alkmaar. US/FNAC was performed preoperatively in all these patients. We analysed the results of US/FNAC retrospectively. Pathological axillary node status (sentinel node biopsy and/or axillary lymph node dissection) was used as reference standard. A total of 634 (29.8 %) of 2130 patients had axillary lymph node metastases on final histology. 248 node positive patients (11.6 %) had three or more positive lymph nodes. The accuracy of US/FNAC to detect three or more positive lymph nodes was 89.8 %, sensitivity was 44.8 %, specificity was 95.7 %, PPV was 58.1 %, and NPV was 92.9 %. This study shows a more than adequate accuracy of preoperative US/FNAC to detect three or more positive lymph nodes (89.8 %). However, when US/FNAC was chosen as the only axillary staging method, 6.4 % of all patients (false negative group) would have been undertreated and 3.8 % of all patients (false positive group) would have been overtreated according to the ACOSOG Z0011 criteria.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Breast Neoplasms / Sentinel Lymph Node Biopsy Type of study: Diagnostic_studies / Observational_studies / Screening_studies Limits: Adult / Aged / Aged80 / Female / Humans / Middle aged Language: En Journal: Breast Cancer Res Treat Year: 2016 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Breast Neoplasms / Sentinel Lymph Node Biopsy Type of study: Diagnostic_studies / Observational_studies / Screening_studies Limits: Adult / Aged / Aged80 / Female / Humans / Middle aged Language: En Journal: Breast Cancer Res Treat Year: 2016 Document type: Article Affiliation country: