Your browser doesn't support javascript.
loading
Agency for Healthcare Research and Quality (AHRQ) Patient Safety Indicator for Postoperative Respiratory Failure (PSI 11) does not identify accurately patients who received unsafe care.
Nguyen, Michelle C; Moffatt-Bruce, Susan D; Strosberg, David S; Puttmann, Kathleen T; Pan, Yangshu L; Eiferman, Daniel S.
Affiliation
  • Nguyen MC; Department of Surgery, The Ohio State University Medical Center, Columbus, OH. Electronic address: michelle.nguyen@osumc.edu.
  • Moffatt-Bruce SD; Department of Surgery, The Ohio State University Medical Center, Columbus, OH.
  • Strosberg DS; Department of Surgery, The Ohio State University Medical Center, Columbus, OH.
  • Puttmann KT; Department of Surgery, The Ohio State University Medical Center, Columbus, OH.
  • Pan YL; Department of Surgery, The Ohio State University Medical Center, Columbus, OH.
  • Eiferman DS; Department of Surgery, The Ohio State University Medical Center, Columbus, OH.
Surgery ; 160(4): 858-868, 2016 10.
Article in En | MEDLINE | ID: mdl-27528212
ABSTRACT

BACKGROUND:

The Agency for Healthcare Research and Quality Patient Safety Indicator 11 is used to identify postoperative respiratory failure events and detect areas for quality improvement. This study examines the accuracy of Patient Safety Indicator 11 in identifying clinically valid patient safety events.

METHODS:

All cases flagged for Patient Safety Indicator 11 from July 2013 to July 2015 by Agency for Healthcare Research and Quality QI Version 4.5 including International Classification of Diseases-9 codes were evaluated. Code-confirmed cases underwent independent review by 2 physicians. Inpatient electronic medical records were used to identify clinical factors for postoperative respiratory failure in each case to determine if postoperative respiratory failure was a result of unsafe care. The clinical true-positive rate and positive predictive value were calculated.

RESULTS:

A total of 166 postoperative respiratory failure cases were reviewed; 51 were recoded and reversed due to coding or documentation errors; 115 cases met the Agency for Healthcare Research and Quality definition of postoperative respiratory failure. A total of 71 (61.7%) of the 115 cases were false positives and did not reflect unsafe care, while 44 cases were true positives with a positive predictive value of 38.3%. χ(2) analysis did not reveal an association between demographics, clinical characteristics, or operative procedure with true-positive cases.

CONCLUSION:

Administrative coding data for Agency for Healthcare Research and Quality Patient Safety Indicator 11 do not identify accurately patients who received unsafe care when taking into account unpreventable clinical factors causing postoperative respiratory failure. The use of Agency for Healthcare Research and Quality Patient Safety Indicator 11 as a hospital performance measure should be reconsidered until inclusion and exclusion criteria are revised.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Postoperative Complications / Respiratory Insufficiency / Hospital Mortality / Quality Indicators, Health Care Type of study: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Country/Region as subject: America do norte Language: En Journal: Surgery Year: 2016 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Postoperative Complications / Respiratory Insufficiency / Hospital Mortality / Quality Indicators, Health Care Type of study: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Country/Region as subject: America do norte Language: En Journal: Surgery Year: 2016 Document type: Article