Your browser doesn't support javascript.
loading
Influence of experimental conditions on atom column visibility in energy dispersive X-ray spectroscopy.
Dycus, J H; Xu, W; Sang, X; D'Alfonso, A J; Chen, Z; Weyland, M; Allen, L J; Findlay, S D; LeBeau, J M.
Affiliation
  • Dycus JH; Department of Materials Science and Engineering, North Carolina State University, 911 Partners Way Engineering Building 1, Raleigh, NC 27606, USA.
  • Xu W; Department of Materials Science and Engineering, North Carolina State University, 911 Partners Way Engineering Building 1, Raleigh, NC 27606, USA.
  • Sang X; Department of Materials Science and Engineering, North Carolina State University, 911 Partners Way Engineering Building 1, Raleigh, NC 27606, USA.
  • D'Alfonso AJ; School of Physics, University of Melbourne, Parkville, Victoria 3010, Australia.
  • Chen Z; School of Physics and Astronomy, Monash University, Clayton, Victoria 3800, Australia.
  • Weyland M; Monash Centre for Electron Microscopy, Monash University, Clayton, Victoria 3800, Australia; Department of Materials Science and Engineering, Monash University, Clayton, Victoria 3800, Australia.
  • Allen LJ; School of Physics, University of Melbourne, Parkville, Victoria 3010, Australia.
  • Findlay SD; School of Physics and Astronomy, Monash University, Clayton, Victoria 3800, Australia.
  • LeBeau JM; Department of Materials Science and Engineering, North Carolina State University, 911 Partners Way Engineering Building 1, Raleigh, NC 27606, USA. Electronic address: jmlebeau@ncsu.edu.
Ultramicroscopy ; 171: 1-7, 2016 12.
Article in En | MEDLINE | ID: mdl-27584051
ABSTRACT
Here we report the influence of key experimental parameters on atomically resolved energy dispersive X-ray spectroscopy (EDX). In particular, we examine the role of the probe forming convergence semi-angle, sample thickness, lattice spacing, and dwell/collection time. We show that an optimum specimen-dependent probe forming convergence angle exists to maximize the signal-to-noise ratio of the atomically resolved signal in EDX mapping. Furthermore, we highlight that it can be important to select an appropriate dwell time to efficiently process the X-ray signal. These practical considerations provide insight for experimental parameters in atomic resolution energy dispersive X-ray analysis.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Ultramicroscopy Year: 2016 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Ultramicroscopy Year: 2016 Document type: Article Affiliation country: