Iatrogenic Cardiac Tamponade During Endovascular Aortic and Mesenteric Stent Grafting: A Case Report.
Haller, Ingrid; Lederer, Wolfgang; Stichlberger, Martina; Posch, Lydia; Rehwald, Rafael; Freund, Martin C; Glodny, Bernhard; Wiedermann, Franz J.
Affiliation
  • Haller I; From the *Department of Anaesthesiology and Critical Care Medicine; †Department of Vascular Surgery; and ‡Department of Radiology, Medical University of Innsbruck, Innsbruck, Austria.
A A Case Rep ; 8(6): 142-144, 2017 Mar 15.
Article in En | MEDLINE | ID: mdl-27941482
ABSTRACT
The authors report a case of left ventricular perforation and cardiac tamponade in a patient undergoing endovascular aortic and mesenteric stent grafting. During the procedure, the anesthetist noticed a sudden increase in central venous pressure and a decrease in blood pressure. Cardiac tamponade was suspected and confirmed by transesophageal echocardiography. Pericardiotomy resulted only in temporary stabilization. Emergency sternotomy revealed left ventricular perforation. Both anesthetists and radiologists have to be aware of such rare but severe complications of interventional procedures.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Aortic Aneurysm / Cardiac Tamponade / Stents / Endovascular Procedures / Heart Injuries / Heart Ventricles / Iatrogenic Disease / Mesenteric Arteries Limits: Aged / Humans / Male Language: En Journal: A A Case Rep Year: 2017 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Aortic Aneurysm / Cardiac Tamponade / Stents / Endovascular Procedures / Heart Injuries / Heart Ventricles / Iatrogenic Disease / Mesenteric Arteries Limits: Aged / Humans / Male Language: En Journal: A A Case Rep Year: 2017 Document type: Article Affiliation country: