Your browser doesn't support javascript.
loading
Comparative Cohort Study of Percutaneous Pedicle Screw Implantation without Versus with Navigation in Patients Undergoing Surgery for Degenerative Lumbar Disc Disease.
Fomekong, Edward; Pierrard, Julien; Raftopoulos, Christian.
Affiliation
  • Fomekong E; Department of Neurosurgery, Cliniques Universitaires Saint-Luc Bruxelles, Brussels, Belgium.
  • Pierrard J; Department of Neurosurgery, Cliniques Universitaires Saint-Luc Bruxelles, Brussels, Belgium.
  • Raftopoulos C; Department of Neurosurgery, Cliniques Universitaires Saint-Luc Bruxelles, Brussels, Belgium. Electronic address: christian.raftopoulos@uclouvain.be.
World Neurosurg ; 111: e410-e417, 2018 Mar.
Article in En | MEDLINE | ID: mdl-29274453
ABSTRACT

BACKGROUND:

The major limitation of computer-based three-dimensional fluoroscopy is increased radiation exposure of patients and operating room staff. Combining spine navigation with intraoperative three-dimensional fluoroscopy (io3DF) can likely overcome this shortcoming, while increasing pedicle screw accuracy rate. We compared data from a cohort of patients undergoing lumbar percutaneous pedicle screw placement using io3DF alone or in combination with spine navigation.

METHODS:

This study consisted of 168 patients who underwent percutaneous pedicle screw implantation between 2009 and 2016. The primary endpoint was to compare pedicle screw accuracy between the 2 groups. Secondary endpoints were to compare radiation exposure of patients and operating room staff, duration of surgery, and postoperative complications.

RESULTS:

In group 1, 438 screws were placed without navigation guidance; in group 2, 276 screws were placed with spine navigation. Mean patient age in both groups was 58.6 ± 14.1 years. The final pedicle accuracy rate was 97.9% in group 1 and 99.6% in group 2. Average radiation dose per patient was significantly larger in group 1 (571.9 mGym2) than in group 2 (365.6 mGym2) (P = 0.000088). Surgery duration and complication rate were not significantly different between the 2 groups (P > 0.05).

CONCLUSIONS:

io3DF with spine navigation minimized radiation exposure of patients and operating room staff and provided an excellent percutaneous pedicle screw accuracy rate with no permanent complications compared with io3DF alone. This setup is recommended, especially for patients with a complex degenerative spine condition.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Stereotaxic Techniques / Diskectomy, Percutaneous / Imaging, Three-Dimensional / Surgery, Computer-Assisted / Intervertebral Disc Degeneration Type of study: Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: World Neurosurg Journal subject: NEUROCIRURGIA Year: 2018 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Stereotaxic Techniques / Diskectomy, Percutaneous / Imaging, Three-Dimensional / Surgery, Computer-Assisted / Intervertebral Disc Degeneration Type of study: Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: World Neurosurg Journal subject: NEUROCIRURGIA Year: 2018 Document type: Article Affiliation country: