Your browser doesn't support javascript.
loading
Dynamic CT for Parathyroid Adenoma Detection: How Does Radiation Dose Compare With Nuclear Medicine?
Czarnecki, Caroline A; Einsiedel, Paul F; Phal, Pramit M; Miller, Julie A; Lichtenstein, Meir; Stella, Damien L.
Affiliation
  • Czarnecki CA; 1 Department of Radiology, The Royal Melbourne Hospital, Parkville, Victoria, Australia.
  • Einsiedel PF; 2 Present address: Frankston Hospital, 1 Hastings Rd, Frankston 3199, Victoria, Australia.
  • Phal PM; 1 Department of Radiology, The Royal Melbourne Hospital, Parkville, Victoria, Australia.
  • Miller JA; 1 Department of Radiology, The Royal Melbourne Hospital, Parkville, Victoria, Australia.
  • Lichtenstein M; 3 Present address: Epworth Medical Imaging, Epworth Richmond, Victoria, Australia.
  • Stella DL; 4 Endocrine Surgery Unit, The Royal Melbourne Hospital, Parkville, Victoria, Australia.
AJR Am J Roentgenol ; 210(5): 1118-1122, 2018 May.
Article in En | MEDLINE | ID: mdl-29629803
OBJECTIVE: Dynamic CT is increasingly used for preoperative localization of parathyroid adenomas, but concerns remain about the radiation effective dose of CT compared with that of 99mTc-sestamibi scintigraphy. The purpose of this study was to compare the radiation dose delivered by three-phase dynamic CT with that delivered by 99mTc-sestamibi SPECT/CT performed in accordance with our current protocols and to assess the possible reduction in effective dose achieved by decreasing the scan length (i.e., z-axis) of two phases of the dynamic CT protocol. MATERIALS AND METHODS: The effective dose of a 99mTc-sestamibi nuclear medicine parathyroid study performed with and without coregistration CT was calculated and compared with the effective dose of our current three-phase dynamic CT protocol as well as a proposed protocol involving CT with reduced scan length. RESULTS: The median effective dose for a 99mTc-sestamibi nuclear medicine study was 5.6 mSv. This increased to 12.4 mSv with the addition of coregistration CT, which is higher than the median effective dose of 9.3 mSv associated with the dynamic CT protocol. Reducing the scan length of two phases in the dynamic CT protocol could reduce the median effective dose to 6.1 mSv, which would be similar to that of the dose from the 99mTc-sestamibi study alone. CONCLUSION: Dynamic CT used for the detection of parathyroid adenoma can deliver a lower radiation dose than 99mTc-sestamibi SPECT/CT. It may be possible to reduce the dose further by decreasing the scan length of two of the phases, although whether this has an impact on accuracy of the localization needs further investigation.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Parathyroid Neoplasms / Radiation Dosage / Radionuclide Imaging / Tomography, X-Ray Computed / Adenoma Type of study: Diagnostic_studies Limits: Aged / Female / Humans / Male Language: En Journal: AJR Am J Roentgenol Year: 2018 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Parathyroid Neoplasms / Radiation Dosage / Radionuclide Imaging / Tomography, X-Ray Computed / Adenoma Type of study: Diagnostic_studies Limits: Aged / Female / Humans / Male Language: En Journal: AJR Am J Roentgenol Year: 2018 Document type: Article Affiliation country: Country of publication: