Laboratory sample stability. Is it possible to define a consensus stability function? An example of five blood magnitudes.
Gómez Rioja, Rubén; Martínez Espartosa, Débora; Segovia, Marta; Ibarz, Mercedes; Llopis, María Antonia; Bauça, Josep Miquel; Marzana, Itziar; Barba, Nuria; Ventura, Monserrat; García Del Pino, Isabel; Puente, Juan José; Caballero, Andrea; Gómez, Carolina; García Álvarez, Ana; Alsina, María Jesús; Álvarez, Virtudes.
Affiliation
  • Gómez Rioja R; La Paz - Cantoblanco - Carlos III University Hospital - Laboratory Medicine, Madrid, Spain.
  • Martínez Espartosa D; Sociedad Española de Medicina de Laboratorio - Comisión de Calidad Extra analítica, Barcelona, Spain.
  • Segovia M; Sociedad Española de Medicina de Laboratorio - Comisión de Calidad Extra analítica, Barcelona, Spain.
  • Ibarz M; Clínica Universidad de Navarra - Laboratory Medicine, Madrid, Spain.
  • Llopis MA; La Paz - Cantoblanco - Carlos III University Hospital - Laboratory Medicine, Madrid, Spain.
  • Bauça JM; Sociedad Española de Medicina de Laboratorio - Comisión de Calidad Extra analítica, Barcelona, Spain.
  • Marzana I; Sociedad Española de Medicina de Laboratorio - Comisión de Calidad Extra analítica, Barcelona, Spain.
  • Barba N; Hospital Universitari Arnau de Vilanova - Laboratori Clínic Territorial ICS, IRB Lleida, Lleida, Catalunya, Spain.
  • Ventura M; Sociedad Española de Medicina de Laboratorio - Comisión de Calidad Extra analítica, Barcelona, Spain.
  • García Del Pino I; Hospital Universitari Germans Trias i Pujol - Laboratory Medicine, Badalona, Spain.
  • Puente JJ; Sociedad Española de Medicina de Laboratorio - Comisión de Calidad Extra analítica, Barcelona, Spain.
  • Caballero A; Department of Laboratory Medicine, Hospital Universitari Son Espases, Palma de Mallorca, Illes Balears, Spain.
  • Gómez C; Sociedad Española de Medicina de Laboratorio - Comisión de Calidad Extra analítica, Barcelona, Spain.
  • García Álvarez A; Hospital Universitario Cruces - Laboratory, Barakaldo, País Vasco, Spain.
  • Alsina MJ; Sociedad Española de Medicina de Laboratorio - Comisión de Calidad Extra analítica, Barcelona, Spain.
  • Álvarez V; CatLab - Laboratory, Viladecavalls, Barcelona, Spain.
Clin Chem Lab Med ; 56(11): 1806-1818, 2018 10 25.
Article in En | MEDLINE | ID: mdl-29729140
BACKGROUND: The stability limit of an analyte in a biological sample can be defined as the time required until a measured property acquires a bias higher than a defined specification. Many studies assessing stability and presenting recommendations of stability limits are available, but differences among them are frequent. The aim of this study was to classify and to grade a set of bibliographic studies on the stability of five common blood measurands and subsequently generate a consensus stability function. METHODS: First, a bibliographic search was made for stability studies for five analytes in blood: alanine aminotransferase (ALT), glucose, phosphorus, potassium and prostate specific antigen (PSA). The quality of every study was evaluated using an in-house grading tool. Second, the different conditions of stability were uniformly defined and the percent deviation (PD%) over time for each analyte and condition were scattered while unifying studies with similar conditions. RESULTS: From the 37 articles considered as valid, up to 130 experiments were evaluated and 629 PD% data were included (106 for ALT, 180 for glucose, 113 for phosphorus, 145 for potassium and 85 for PSA). Consensus stability equations were established for glucose, potassium, phosphorus and PSA, but not for ALT. CONCLUSIONS: Time is the main variable affecting stability in medical laboratory samples. Bibliographic studies differ in recommedations of stability limits mainly because of different specifications for maximum allowable error. Definition of a consensus stability function in specific conditions can help laboratories define stability limits using their own quality specifications.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Blood Specimen Collection Limits: Humans Language: En Journal: Clin Chem Lab Med Journal subject: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Year: 2018 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Blood Specimen Collection Limits: Humans Language: En Journal: Clin Chem Lab Med Journal subject: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Year: 2018 Document type: Article Affiliation country: Country of publication: