Your browser doesn't support javascript.
loading
Acceptability, Accuracy, and Safety of Disposable Transnasal Capsule Endoscopy for Barrett's Esophagus Screening.
Sami, Sarmed S; Iyer, Prasad G; Pophali, Prachi; Halland, Magnus; di Pietro, Massimiliano; Ortiz-Fernandez-Sordo, Jacobo; White, Jonathan R; Johnson, Michele; Guha, Indra Neil; Fitzgerald, Rebecca C; Ragunath, Krish.
Affiliation
  • Sami SS; Barrett's Esophagus Unit, Division of Gastroenterology & Hepatology, Mayo Clinic, Rochester, Minnesota; Division of Surgery and Interventional Science, University College London, London, United Kingdom.
  • Iyer PG; Barrett's Esophagus Unit, Division of Gastroenterology & Hepatology, Mayo Clinic, Rochester, Minnesota.
  • Pophali P; Barrett's Esophagus Unit, Division of Gastroenterology & Hepatology, Mayo Clinic, Rochester, Minnesota.
  • Halland M; Barrett's Esophagus Unit, Division of Gastroenterology & Hepatology, Mayo Clinic, Rochester, Minnesota.
  • di Pietro M; Cambridge University Hospitals NHS Trust and MRC Cancer Unit, Hutchinson/MRC Research Center, University of Cambridge, Cambridge, United Kingdom.
  • Ortiz-Fernandez-Sordo J; National Institute for Health Research Biomedical Research Center in Gastrointestinal and Liver Diseases at Nottingham University Hospitals NHS Trust and the University of Nottingham, Queens Medical Center Campus, Nottingham, United Kingdom.
  • White JR; National Institute for Health Research Biomedical Research Center in Gastrointestinal and Liver Diseases at Nottingham University Hospitals NHS Trust and the University of Nottingham, Queens Medical Center Campus, Nottingham, United Kingdom.
  • Johnson M; Barrett's Esophagus Unit, Division of Gastroenterology & Hepatology, Mayo Clinic, Rochester, Minnesota.
  • Guha IN; National Institute for Health Research Biomedical Research Center in Gastrointestinal and Liver Diseases at Nottingham University Hospitals NHS Trust and the University of Nottingham, Queens Medical Center Campus, Nottingham, United Kingdom.
  • Fitzgerald RC; Cambridge University Hospitals NHS Trust and MRC Cancer Unit, Hutchinson/MRC Research Center, University of Cambridge, Cambridge, United Kingdom.
  • Ragunath K; National Institute for Health Research Biomedical Research Center in Gastrointestinal and Liver Diseases at Nottingham University Hospitals NHS Trust and the University of Nottingham, Queens Medical Center Campus, Nottingham, United Kingdom. Electronic address: k.ragunath@nottingham.ac.uk.
Clin Gastroenterol Hepatol ; 17(4): 638-646.e1, 2019 03.
Article in En | MEDLINE | ID: mdl-30081223
BACKGROUND & AIMS: Screening for Barrett's esophagus (BE) with conventional esophagogastroduodenoscopy (C-EGD) is expensive. We assessed the performance of a clinic-based, single use transnasal capsule endoscope (EG Scan II) for the detection of BE, compared to C-EGD as the reference standard. METHODS: We performed a prospective multicenter cohort study of patients with and without BE recruited from 3 referral centers (1 in the United States and 2 in the United Kingdom). Of 200 consenting participants, 178 (89%) completed both procedures (11% failed EG Scan due to the inability to intubate the nasopharynx). The mean age of participants was 57.9 years and 67% were male. The prevalence of BE was 53%. All subjects underwent the 2 procedures on the same day, performed by blinded endoscopists. Patients completed preference and validated tolerability (10-point visual analogue scale [VAS]) questionnaires within 14 days of the procedures. RESULTS: A higher proportion of patients preferred the EG Scan (54.2%) vs the C-EGD (16.7%) (P < .001) and the EG Scan had a higher VAS score (7.2) vs the C-EGD (6.4) (P = .0004). No serious adverse events occurred. The EG Scan identified any length BE with a sensitivity value of 0.90 (95% CI, 0.83-0.96) and a specificity value of 0.91 (95% CI, 0.82-0.96). The EG Scan identified long segment BE with a sensitivity value of 0.95 and short segment BE with a sensitivity values of 0.87. CONCLUSIONS: In a prospective study, we found the EG Scan to be safe and to detect BE with higher than 90% sensitivity and specificity. A higher proportion of patients preferred the EG Scan to C-EGD. This device might be used as a clinic-based tool to screen populations at risk for BE. ISRCTN registry identifier: 70595405; ClinicalTrials.gov no: NCT02066233.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Barrett Esophagus / Patient Acceptance of Health Care / Mass Screening / Capsule Endoscopy / Patient Safety Type of study: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Country/Region as subject: America do norte / Europa Language: En Journal: Clin Gastroenterol Hepatol Journal subject: GASTROENTEROLOGIA Year: 2019 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Barrett Esophagus / Patient Acceptance of Health Care / Mass Screening / Capsule Endoscopy / Patient Safety Type of study: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Country/Region as subject: America do norte / Europa Language: En Journal: Clin Gastroenterol Hepatol Journal subject: GASTROENTEROLOGIA Year: 2019 Document type: Article Affiliation country: Country of publication: