Gold nanoparticles as labels for immunochemical analysis using laser ablation inductively coupled plasma mass spectrometry.
Tvrdonova, Michaela; Vlcnovska, Marcela; Vanickova, Lucie Pompeiano; Kanicky, Viktor; Adam, Vojtech; Ascher, Lena; Jakubowski, Norbert; Vaculovicova, Marketa; Vaculovic, Tomas.
Affiliation
  • Tvrdonova M; Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 753/5, 625 00, Brno, Czech Republic.
  • Vlcnovska M; CEITEC, Masaryk University, Kamenice 753/5, 625 00, Brno, Czech Republic.
  • Vanickova LP; Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic.
  • Kanicky V; Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic.
  • Adam V; Central European Institute of Technology, Brno University of Technology, Purkynova 123, 612 00, Brno, Czech Republic.
  • Ascher L; Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 753/5, 625 00, Brno, Czech Republic.
  • Jakubowski N; CEITEC, Masaryk University, Kamenice 753/5, 625 00, Brno, Czech Republic.
  • Vaculovicova M; Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, 613 00, Brno, Czech Republic.
  • Vaculovic T; Central European Institute of Technology, Brno University of Technology, Purkynova 123, 612 00, Brno, Czech Republic.
Anal Bioanal Chem ; 411(3): 559-564, 2019 Jan.
Article in En | MEDLINE | ID: mdl-30109381
ABSTRACT
In this paper, we describe the labelling of antibodies by gold nanoparticles (AuNPs) with diameters of 10 and 60 nm with detection by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Additionally, the AuNPs labelling strategy is compared with commercially available labelling reagents based on MeCAT (metal coded affinity tagging). Proof of principle experiments based on dot blot experiments were performed. The two labelling methods investigated were compared by sensitivity and limit of detection (LOD). The absolute LODs achieved were in the range of tens of picograms for AuNP labelling compared to a few hundred picograms by the MeCAT labelling.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Mass Spectrometry / Immunoassay / Metal Nanoparticles / Gold / Lasers / Antibodies Language: En Journal: Anal Bioanal Chem Year: 2019 Document type: Article Affiliation country: