Your browser doesn't support javascript.
loading
Hybrid-stenting with metallic and bioresorbable drug-eluting stents 2-year clinical outcomes in KUM ABSORB registry.
Baquet, Moritz; Grundmann, David; Schmidt, Wolfgang; Thienel, Manuela; Jochheim, David; Tesche, Christian; Theiss, Hans Diogenes; Brunner, Stefan; Massberg, Steffen; Mehilli, Julinda.
Affiliation
  • Baquet M; Department of Cardiology, Munich University Clinic, Ludwigs-Maximilian-University, Germany.
  • Grundmann D; German Centre for Cardiovascular Research, partner site Munich Heart Alliance, Munich, Germany.
  • Schmidt W; Department of Cardiology, Munich University Clinic, Ludwigs-Maximilian-University, Germany.
  • Thienel M; Department of Cardiology, Munich University Clinic, Ludwigs-Maximilian-University, Germany.
  • Jochheim D; Department of Cardiology, Munich University Clinic, Ludwigs-Maximilian-University, Germany.
  • Tesche C; Department of Cardiology, Munich University Clinic, Ludwigs-Maximilian-University, Germany.
  • Theiss HD; German Centre for Cardiovascular Research, partner site Munich Heart Alliance, Munich, Germany.
  • Brunner S; Department of Cardiology, Munich University Clinic, Ludwigs-Maximilian-University, Germany.
  • Massberg S; Department of Cardiology, Munich University Clinic, Ludwigs-Maximilian-University, Germany.
  • Mehilli J; Department of Cardiology, Munich University Clinic, Ludwigs-Maximilian-University, Germany.
Catheter Cardiovasc Interv ; 93(1): 71-78, 2019 01 01.
Article in En | MEDLINE | ID: mdl-30232838

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Coronary Artery Disease / Angioplasty, Balloon, Coronary / Absorbable Implants / Coronary Stenosis / Drug-Eluting Stents Type of study: Etiology_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Catheter Cardiovasc Interv Journal subject: CARDIOLOGIA Year: 2019 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Coronary Artery Disease / Angioplasty, Balloon, Coronary / Absorbable Implants / Coronary Stenosis / Drug-Eluting Stents Type of study: Etiology_studies / Prognostic_studies / Risk_factors_studies Limits: Aged / Female / Humans / Male / Middle aged Language: En Journal: Catheter Cardiovasc Interv Journal subject: CARDIOLOGIA Year: 2019 Document type: Article Affiliation country: Country of publication: