Ultrasensitive amperometric immunosensor for the prostate specific antigen by exploiting a Fenton reaction induced by a metal-organic framework nanocomposite of type Au/Fe-MOF with peroxidase mimicking activity.
Feng, Jiejie; Wang, Huiqiang; Ma, Zhanfang.
Affiliation
  • Feng J; Department of Chemistry, Capital Normal University, Beijing, 100048, China.
  • Wang H; Department of Chemistry, Capital Normal University, Beijing, 100048, China.
  • Ma Z; Department of Chemistry, Capital Normal University, Beijing, 100048, China. mazhanfang@cnu.edu.cn.
Mikrochim Acta ; 187(1): 95, 2020 01 06.
Article in En | MEDLINE | ID: mdl-31903507
ABSTRACT
To increase the sensitivity of electrochemical sensor, Fe-MIL-88B-NH2 (Fe-MOF) with peroxidase-like activity is designed for the construction of immunoprobe. The Fe-MOF was prepared by one-step hydrothermalf method using 2-aminoterephthalic acid and iron(III) chloride. For the immunoprobe, it was fabricated by gold nanocomposite/Fe-MOF (Au/Fe-MOF) for the immobilization of labeling antibody (the antibody was used to conjuncting with label materials). The thin layer of Methylene Blue (MB) covered by reduced graphene oxide-gold nanocomposites (Au-rGO) serves as a substrate to covalently fix coating antibodies. The MB as a redox-active species was modified on the glass carbon electrode that can give a strong amperometric signal at 0.18 V (vs. Ag/AgCl). With the participation of H2O2, Fe-MOF can induce the Fenton reaction which degrades MB covered by Au-rGO on the substrate. The rest of MB on the surface of electrode becomes oxidized thereby generating a current signal. Square wave voltammetry (SWV) was used to quantify PSA. Under optimal conditions, the immunoassay is stable, specific and reproducible. It has a lower detection limit of 0.13 pg mL-1 (S/N = 3) and a wide analytical range that extends from 0.001 to 100 ng mL-1. Graphical abstractA sandwich-type amperometric immunoassay based on Fe-MOF-induced Fenton reaction was designed for sensitive determination of prostate specific antigen.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Kallikreins / Prostate-Specific Antigen / Peroxidase / Nanocomposites / Electrochemical Techniques / Metal-Organic Frameworks Limits: Humans Language: En Journal: Mikrochim Acta Year: 2020 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Kallikreins / Prostate-Specific Antigen / Peroxidase / Nanocomposites / Electrochemical Techniques / Metal-Organic Frameworks Limits: Humans Language: En Journal: Mikrochim Acta Year: 2020 Document type: Article Affiliation country: