Your browser doesn't support javascript.
loading
Evaluation of complications after endoscopic retrograde cholangiopancreatography using a short type double balloon endoscope in patients with altered gastrointestinal anatomy: a single-center retrospective study of 1,576 procedures.
Tokuhara, Mitsuo; Shimatani, Masaaki; Mitsuyama, Toshiyuki; Masuda, Masataka; Ito, Takashi; Miyamoto, Sachi; Fukata, Norimasa; Miyoshi, Hideaki; Ikeura, Tsukasa; Takaoka, Makoto; Kouda, Katsuyasu; Okazaki, Kazuichi.
Affiliation
  • Tokuhara M; Third Department of Internal Medicine, Division of Gastroenterology and Hepatology, Kansai Medical University Hirakata Hospital, Osaka, Japan.
  • Shimatani M; Third Department of Internal Medicine, Division of Gastroenterology and Hepatology, Kansai Medical University Hirakata Hospital, Osaka, Japan.
  • Mitsuyama T; Third Department of Internal Medicine, Division of Gastroenterology and Hepatology, Kansai Medical University Hirakata Hospital, Osaka, Japan.
  • Masuda M; Third Department of Internal Medicine, Division of Gastroenterology and Hepatology, Kansai Medical University Hirakata Hospital, Osaka, Japan.
  • Ito T; Third Department of Internal Medicine, Division of Gastroenterology and Hepatology, Kansai Medical University Hirakata Hospital, Osaka, Japan.
  • Miyamoto S; Third Department of Internal Medicine, Division of Gastroenterology and Hepatology, Kansai Medical University Hirakata Hospital, Osaka, Japan.
  • Fukata N; Third Department of Internal Medicine, Division of Gastroenterology and Hepatology, Kansai Medical University Hirakata Hospital, Osaka, Japan.
  • Miyoshi H; Third Department of Internal Medicine, Division of Gastroenterology and Hepatology, Kansai Medical University Hirakata Hospital, Osaka, Japan.
  • Ikeura T; Third Department of Internal Medicine, Division of Gastroenterology and Hepatology, Kansai Medical University Hirakata Hospital, Osaka, Japan.
  • Takaoka M; Third Department of Internal Medicine, Division of Gastroenterology and Hepatology, Kansai Medical University Hirakata Hospital, Osaka, Japan.
  • Kouda K; Department of Hygiene and Public Health, Kansai Medical University Hirakata Hospital, Osaka, Japan.
  • Okazaki K; Third Department of Internal Medicine, Division of Gastroenterology and Hepatology, Kansai Medical University Hirakata Hospital, Osaka, Japan.
J Gastroenterol Hepatol ; 35(8): 1387-1396, 2020 Aug.
Article in En | MEDLINE | ID: mdl-32103516
BACKGROUND AND AIM: Endoscopic retrograde cholangiopancreatography (ERCP) using balloon-assisted endoscope such as double-balloon endoscope is even effective for patients with surgically altered anatomy. Yet comprehensive studies on complications of ERCP using balloon-assisted endoscope have not been made. We analyzed the characteristics and the causes of complications of ERCP using double-balloon endoscope (DB-ERCP) procedures and aimed to suggest effective managements. METHODS: A total of 1576 procedures of DB-ERCP in 714 patients with surgically altered gastrointestinal anatomy in our hospital were evaluated retrospectively using a statistic analysis. RESULTS: The overall complication occurrence rate was 5.8%. By type of complications are perforation 3.2%, mucosal laceration 0.5%, hemorrhage 1.0%, pancreatitis 0.6%, respiratory disorder 0.4%, and others 0.2%. By type of surgical reconstruction methods were Roux-en-Y reconstruction with choledocho-jejunal anastomosis 4.2%, Roux-en-Y reconstruction without choledocho-jejunal anastomosis 6.7%, pancreaticoduodenectomy 4.5%, pylorus preserving pancreaticoduodenectomy 4.2%, Billroth II gastrectomy (B-II) 11.6%, and other reconstruction method (others) 7.4%. The contributing factors calculated by a multivariate analysis were B-II (odds ratio: 1.864, 95% confidence interval: 1.001-3.471, P = 0.050) and the presence of naïve papilla (odds ratio: 3.268, 95% confidence interval: 1.426-7.490, P = 0.005). CONCLUSIONS: DB-ERCP is a safe method with a total complication rate of 5.8% that could be considered within an acceptable range. The most common complication was the injury of the digestive tract such as perforation. Affecting risk factors for complications were B-II and the presence of naïve papilla. DB-ERCP procedures should be performed carefully of these factors.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Postoperative Complications / Cholangiopancreatography, Endoscopic Retrograde / Endoscopes, Gastrointestinal Type of study: Etiology_studies / Observational_studies / Risk_factors_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: J Gastroenterol Hepatol Journal subject: GASTROENTEROLOGIA Year: 2020 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Postoperative Complications / Cholangiopancreatography, Endoscopic Retrograde / Endoscopes, Gastrointestinal Type of study: Etiology_studies / Observational_studies / Risk_factors_studies Limits: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Language: En Journal: J Gastroenterol Hepatol Journal subject: GASTROENTEROLOGIA Year: 2020 Document type: Article Affiliation country: Country of publication: