Short- and mid-term influence of drug-coated stent implantation on structural and functional vascular healing response: An optical coherence tomography and acetylcholine testing study.
Tamaru, Hiroto; Fujii, Kenichi; Otsuji, Satoru; Takiuchi, Shin; Hasegawa, Katsuyuki; Ishibuchi, Kasumi; Ishii, Rui; Yamamoto, Wataru; Nakabayashi, Sho; Higashino, Yorihiko.
Affiliation
  • Tamaru H; Department of Cardiology, Higashi Takarazuka Satoh Hospital, Takarazuka, Japan.
  • Fujii K; Division of Cardiology, Department of Medicine II, Kansai Medical University, Hirakata, Japan.
  • Otsuji S; Department of Cardiology, Higashi Takarazuka Satoh Hospital, Takarazuka, Japan.
  • Takiuchi S; Department of Cardiology, Higashi Takarazuka Satoh Hospital, Takarazuka, Japan.
  • Hasegawa K; Department of Cardiology, Higashi Takarazuka Satoh Hospital, Takarazuka, Japan.
  • Ishibuchi K; Department of Cardiology, Higashi Takarazuka Satoh Hospital, Takarazuka, Japan.
  • Ishii R; Department of Cardiology, Higashi Takarazuka Satoh Hospital, Takarazuka, Japan.
  • Yamamoto W; Department of Cardiology, Higashi Takarazuka Satoh Hospital, Takarazuka, Japan.
  • Nakabayashi S; Department of Cardiology, Higashi Takarazuka Satoh Hospital, Takarazuka, Japan.
  • Higashino Y; Department of Cardiology, Higashi Takarazuka Satoh Hospital, Takarazuka, Japan.
Catheter Cardiovasc Interv ; 97(2): E186-E193, 2021 02 01.
Article in En | MEDLINE | ID: mdl-32384590
OBJECTIVE: This study investigated the effect of a drug-coated stent (DCS) that has a novel microporous abluminal surface without a polymer on 1-month and 1-year functional and morphological healing response as assessed using acetylcholine (Ach) testing and optical coherence tomography (OCT). BACKGROUND: DCS is expected to induce favorable morphological and physiological arterial healing after its implantation. METHODS: A total of 11 patients who underwent vascular response examinations 1-month and 1-year after the index PCI with DCS implantation were enrolled. The vascular response was evaluated by the functional response test by acetylcholine infusion, the morphological response test by OCT. RESULTS: Although 94.5% of the DCS struts were covered by homogeneous smooth neointima at 1 month, the percentage of neointimal coverage increased to 98.5% at 1 year (p = .02). Conversely, the proportion of uncovered struts and malapposed struts at 1 year were 1.2 and 0.7%, respectively. Furthermore, the coronary vasomotor response to incremental doses of Ach were impaired especially in the distal segments at each period, although the responses to Ach at 10-6 mol/L in the distal segment tended to improve over time from baseline to 1 month and 1 year later (-19 ± 20%, -9 ± 17%, and -5 ± 14%, respectively; p = .27). CONCLUSIONS: The morphological assessment of DCS with OCT revealed a high degree of strut coverage and apposition at 4 weeks after implantation. The impaired endothelium-dependent vasomotor response tended to improve chronologically from baseline to 1 month and 1 year later.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Coronary Artery Disease / Drug-Eluting Stents / Percutaneous Coronary Intervention Limits: Humans Language: En Journal: Catheter Cardiovasc Interv Journal subject: CARDIOLOGIA Year: 2021 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Coronary Artery Disease / Drug-Eluting Stents / Percutaneous Coronary Intervention Limits: Humans Language: En Journal: Catheter Cardiovasc Interv Journal subject: CARDIOLOGIA Year: 2021 Document type: Article Affiliation country: Country of publication: