Correlation between eye lens doses and over apron doses in interventional procedures.
Gracia-Ochoa, M; Candela-Juan, C; Vilar-Palop, J; Ruiz Rodríguez, J C; Soriano Cruz, A; Palma Copete, J D; Pujades Claumarchirant, M C; Llorca Domaica, N.
Affiliation
  • Gracia-Ochoa M; Centro Nacional de Dosimetría (CND), Avda de Campanar, 21, 46009 Valencia Spain. Electronic address: mgracia@ingesa.sanidad.gob.es.
  • Candela-Juan C; Centro Nacional de Dosimetría (CND), Avda de Campanar, 21, 46009 Valencia Spain.
  • Vilar-Palop J; Centro Nacional de Dosimetría (CND), Avda de Campanar, 21, 46009 Valencia Spain.
  • Ruiz Rodríguez JC; Centro Nacional de Dosimetría (CND), Avda de Campanar, 21, 46009 Valencia Spain.
  • Soriano Cruz A; Centro Nacional de Dosimetría (CND), Avda de Campanar, 21, 46009 Valencia Spain.
  • Palma Copete JD; Centro Nacional de Dosimetría (CND), Avda de Campanar, 21, 46009 Valencia Spain.
  • Pujades Claumarchirant MC; Centro Nacional de Dosimetría (CND), Avda de Campanar, 21, 46009 Valencia Spain.
  • Llorca Domaica N; Centro Nacional de Dosimetría (CND), Avda de Campanar, 21, 46009 Valencia Spain.
Phys Med ; 77: 10-17, 2020 Sep.
Article in En | MEDLINE | ID: mdl-32763729
ABSTRACT
Measurements of eye lens dose using over apron dosimeters with a geometric correction factor is an international accepted practice. However, further knowledge regarding geometric correction factors in different contexts is required. The authors studied the correlation between eye lens dose and over apron dosimetry for different medical specialties in eleven hospitals, using a standardized protocol, two independent over apron dosimeters (worn at chest and at neck levels) and a dedicated calibration procedure. The results show good correlation between subjects working on the same medical specialty for 5 specialties Interventional Radiology, Vascular Surgery, Vascular Radiology, Hemodynamics and Neuroradiology. The geometric correction factors resulting from this study could be used to estimate eye lens dose using over apron dosimeters, which are more comfortable than eye lens dosimeters, as reported by the study subjects, as long as the increased uncertainty of the over apron dosimetry compared to the dedicated eye lens dosimetry is acceptable.