Your browser doesn't support javascript.
loading
Evaluation of a Tube Voltage-Tailored Contrast Medium Injection Protocol for Coronary CT Angiography: Results From the Prospective VOLCANIC Study.
Martin, Simon S; Giovagnoli, Dante A; Abadia, Andres F; Vingiani, Vincenzo; Doeberitz, Philipp L von Knebel; Smith, Hubert E; Fischer, Andreas M; Varga-Szemes, Akos; Vogl, Thomas J; De Cecco, Carlo N; Schoepf, U Joseph.
Affiliation
  • Martin SS; Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC.
  • Giovagnoli DA; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany.
  • Abadia AF; Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC.
  • Vingiani V; Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC.
  • Doeberitz PLVK; Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC.
  • Smith HE; Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC.
  • Fischer AM; Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
  • Varga-Szemes A; Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC.
  • Vogl TJ; Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC.
  • De Cecco CN; Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Medical University of South Carolina, Charleston, SC.
  • Schoepf UJ; Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt, Germany.
AJR Am J Roentgenol ; 215(5): 1049-1056, 2020 11.
Article in En | MEDLINE | ID: mdl-32960669
ABSTRACT
OBJECTIVE. The purpose of this study was to prospectively evaluate, using software support, the feasibility and the quantitative and qualitative image quality parameters of a tube voltage-tailored contrast medium (CM) application protocol for patient-specific injection during coronary CT angiography (CCTA). SUBJECTS AND METHODS. In the Voltage-Based Contrast Media Adaptation in Coronary Computed Tomography Angiography (VOLCANIC-CTA) study, a single-center trial, 120 patients referred for CCTA were prospectively assigned to a tube voltage-tailored CM injection protocol. Automated tube voltage levels were selected in 10-kV intervals and ranged from 70 to 130 kV, and the iodine delivery rate (IDR) was adapted to the tube voltage level using dedicated software. The administered CM volume (370 mg I/mL) ranged from 33 mL at 70 kV (IDR, 0.7 g I/s) to 65 mL at 130 kV (IDR, 1.7 g I/s). Attenuation was measured in the aorta and coronary arteries to calculate quantitative signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and 5-point scales were used to evaluate overall image quality. Radiation metrics were also assessed and compared among the protocols. RESULTS. The mean age of the study patients was 62.5 ± 11.9 (SD) years. Image quality was rated as diagnostic in all patients. Contrast attenuation peaked at 70 kV (p < 0.001), whereas SNR and CNR parameters showed no significant differences between tube voltage levels (p ≥ 0.085). Additionally, no significant differences in subjective image quality parameters were found among the different protocols (p ≥ 0.139). The lowest radiation dose values were observed in the group assigned to the 70-kV protocol, which had a median radiation effective dose of 2.0 mSv (p < 0.001). CONCLUSION. The proposed tube voltage-tailored injection protocol allows individualized scanning of patients undergoing CCTA and significantly reduces CM and radiation dose while maintaining a high diagnostic image quality.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Coronary Angiography / Contrast Media / Computed Tomography Angiography Type of study: Guideline / Observational_studies / Qualitative_research Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: AJR Am J Roentgenol Year: 2020 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Coronary Angiography / Contrast Media / Computed Tomography Angiography Type of study: Guideline / Observational_studies / Qualitative_research Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: AJR Am J Roentgenol Year: 2020 Document type: Article Affiliation country: