Your browser doesn't support javascript.
loading
Organic Field-Effect Transistors as Flexible, Tissue-Equivalent Radiation Dosimeters in Medical Applications.
Zeidell, Andrew M; Ren, Tong; Filston, David S; Iqbal, Hamna F; Holland, Emma; Bourland, J Daniel; Anthony, John E; Jurchescu, Oana D.
Affiliation
  • Zeidell AM; Department of Physics and Center for Functional Materials Wake Forest University Winston-Salem NC 27109 USA.
  • Ren T; Department of Radiation Oncology Wake Forest School of Medicine Wake Forest University Winston Salem NC 27157 USA.
  • Filston DS; Department of Physics and Center for Functional Materials Wake Forest University Winston-Salem NC 27109 USA.
  • Iqbal HF; Department of Physics and Center for Functional Materials Wake Forest University Winston-Salem NC 27109 USA.
  • Holland E; University of Kentucky Center for Applied Energy Research Lexington KY 40511 USA.
  • Bourland JD; Department of Radiation Oncology Wake Forest School of Medicine Wake Forest University Winston Salem NC 27157 USA.
  • Anthony JE; University of Kentucky Center for Applied Energy Research Lexington KY 40511 USA.
  • Jurchescu OD; Department of Physics and Center for Functional Materials Wake Forest University Winston-Salem NC 27109 USA.
Adv Sci (Weinh) ; 7(18): 2001522, 2020 Sep.
Article in En | MEDLINE | ID: mdl-32999849
Radiation therapy is one of the most prevalent procedures for cancer treatment, but the risks of malignancies induced by peripheral beam in healthy tissues surrounding the target is high. Therefore, being able to accurately measure the exposure dose is a critical aspect of patient care. Here a radiation detector based on an organic field-effect transistor (RAD-OFET) is introduced, an in vivo dosimeter that can be placed directly on a patient's skin to validate in real time the dose being delivered and ensure that for nearby regions an acceptable level of low dose is being received. This device reduces the errors faced by current technologies in approximating the dose profile in a patient's body, is sensitive for doses relevant to radiation treatment procedures, and robust when incorporated into conformal large-area electronics. A model is proposed to describe the operation of RAD-OFETs, based on the interplay between charge photogeneration and trapping.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Adv Sci (Weinh) Year: 2020 Document type: Article Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Adv Sci (Weinh) Year: 2020 Document type: Article Country of publication: