Molecularly imprinted polymer-based device for field collection of oral fluid samples for cocaine identification.
J Chromatogr A
; 1633: 461629, 2020 Dec 06.
Article
in En
| MEDLINE
| ID: mdl-33128968
In this paper, a low-cost, rapid, easy, and potentially portable tool for the identification of cocaine and its semi-quantitative determination in oral fluid has been proposed. A field collection device has been designed, based on a cotton pad with an indicator and a molecularly imprinted polymer (MIP) sorbent, to selective retain cocaine from oral fluid components. After sample collection, cocaine is transferred by using phosphate buffer to the MIP and then eluted with 2-propanol. The obtained extract is analysed by ion mobility spectrometry (IMS), providing a cut-off value of 20 µg L-1 that identifies 100 % true-positive and 95 % true-negative samples. The MIP-IMS procedure has been validated by the analysis of oral fluid samples, collected from cocaine users at recreation environments, by comparing the results with lateral flow immunoassay and chromatographic reference methods. Thus, the proposed methodology allows a simple and fast cocaine identification that can be carried out in field by non-specialized personnel, such as health personnel, law enforcement bodies, and customs staff.
Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Saliva
/
Substance Abuse Detection
/
Cocaine
/
Molecular Imprinting
Type of study:
Diagnostic_studies
Limits:
Humans
Language:
En
Journal:
J Chromatogr A
Year:
2020
Document type:
Article
Affiliation country:
Country of publication: