Your browser doesn't support javascript.
loading
Line-FRAP, A Versatile Method to Measure Diffusion Rates In Vitro and In Vivo.
Dey, Debabrata; Marciano, Shir; Nunes-Alves, Ariane; Kiss, Vladimir; Wade, Rebecca C; Schreiber, Gideon.
Affiliation
  • Dey D; Department of Biomolecular Sciences, Weizmann Institute of Science, Israel.
  • Marciano S; Department of Biomolecular Sciences, Weizmann Institute of Science, Israel.
  • Nunes-Alves A; Molecular and Cellular Modeling Group, Heidelberg Institute for Theoretical Studies, Schloss-Wolfsbrunnenweg 35, 69118 Heidelberg, Germany; Center for Molecular Biology (ZMBH), DKFZ-ZMBH Alliance, Heidelberg University, Im Neuenheimer Feld 282, 69120 Heidelberg, Germany.
  • Kiss V; Department of Biomolecular Sciences, Weizmann Institute of Science, Israel.
  • Wade RC; Molecular and Cellular Modeling Group, Heidelberg Institute for Theoretical Studies, Schloss-Wolfsbrunnenweg 35, 69118 Heidelberg, Germany; Center for Molecular Biology (ZMBH), DKFZ-ZMBH Alliance, Heidelberg University, Im Neuenheimer Feld 282, 69120 Heidelberg, Germany; Interdisciplinary Center for
  • Schreiber G; Department of Biomolecular Sciences, Weizmann Institute of Science, Israel. Electronic address: gideon.schreiber@weizmann.ac.il.
J Mol Biol ; 433(9): 166898, 2021 04 30.
Article in En | MEDLINE | ID: mdl-33647289
ABSTRACT
The crowded cellular milieu affect molecular diffusion through hard (occluded space) and soft (weak, non-specific) interactions. Multiple methods have been developed to measure diffusion coefficients at physiological protein concentrations within cells, each with its limitations. Here, we show that Line-FRAP, combined with rigours data analysis, is able to determine diffusion coefficients in a variety of environments, from in vitro to in vivo. The use of Line mode greatly improves time resolution of FRAP data acquisition, from 20-100 Hz in the classical mode to 800 Hz in the line mode. This improves data analysis, as intensity and radius of the bleach at the first post-bleach frame is critical. We evaluated the method on different proteins labelled chemically or fused to YFP in a wide range of environments. The diffusion coefficients measured in HeLa and in E. coli were ~2.5-fold and 15-fold slower than in buffer, and were comparable to previously published data. Increasing the osmotic pressure on E. coli further decreases diffusion, to the point at which proteins virtually stop moving. The method presented here, which requires a confocal microscope equipped with dual scanners, can be applied to study a large range of molecules with different sizes, and provides robust results in a wide range of environments and protein concentrations for fast diffusing molecules.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Proteins / Fluorescence Recovery After Photobleaching / Diffusion Limits: Humans Language: En Journal: J Mol Biol Year: 2021 Document type: Article Affiliation country: Publication country: HOLANDA / HOLLAND / NETHERLANDS / NL / PAISES BAJOS / THE NETHERLANDS

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Proteins / Fluorescence Recovery After Photobleaching / Diffusion Limits: Humans Language: En Journal: J Mol Biol Year: 2021 Document type: Article Affiliation country: Publication country: HOLANDA / HOLLAND / NETHERLANDS / NL / PAISES BAJOS / THE NETHERLANDS