Your browser doesn't support javascript.
loading
Development and Validation of an Objective Scoring Tool for Robot-Assisted Partial Nephrectomy: Scoring for Partial Nephrectomy.
Iqbal, Umar; Jing, Zhe; Ahmed, Youssef; Elsayed, Ahmed S; Rogers, Craig; Boris, Ronald; Porter, James; Allaf, Mohammad; Badani, Ketan; Stifelman, Michael; Kaouk, Jihad; Terakawa, Tomoaki; Hinata, Nobuyuki; Aboumohamed, Ahmed A; Kauffman, Eric; Li, Qiang; Abaza, Ronney; Guru, Khurshid A; Hussein, Ahmed A; Eun, Daniel.
Affiliation
  • Iqbal U; A.T.L.A.S. (Applied Technology Laboratory for Advanced Surgery), Roswell Park Comprehensive Cancer Center, Buffalo, New York, USA.
  • Jing Z; A.T.L.A.S. (Applied Technology Laboratory for Advanced Surgery), Roswell Park Comprehensive Cancer Center, Buffalo, New York, USA.
  • Ahmed Y; A.T.L.A.S. (Applied Technology Laboratory for Advanced Surgery), Roswell Park Comprehensive Cancer Center, Buffalo, New York, USA.
  • Elsayed AS; A.T.L.A.S. (Applied Technology Laboratory for Advanced Surgery), Roswell Park Comprehensive Cancer Center, Buffalo, New York, USA.
  • Rogers C; Cairo University, Cairo, Egypt.
  • Boris R; Henry Ford Health Systems, Detroit, Michigan, USA.
  • Porter J; Indiana University School of Medicine, Indianapolis, Indiana, USA.
  • Allaf M; Swedish Medical Center, Seattle, Washington, USA.
  • Badani K; Johns Hopkins University Hospital, Boston, Massachusetts, USA.
  • Stifelman M; Icahn School of Medicine at Mount Sinai, New York, New York, USA.
  • Kaouk J; Hackensack Meridian School of Medicine, Hackensack, New Jersey, USA.
  • Terakawa T; Cleveland Clinic, Cleveland, Ohio, USA.
  • Hinata N; Kobe University, Kobe, Japan.
  • Aboumohamed AA; Hiroshima University Graduate School of Biomedical and Health Sciences, Hiroshima, Japan.
  • Kauffman E; Montefiore Medical Center, New York, New York, USA.
  • Li Q; A.T.L.A.S. (Applied Technology Laboratory for Advanced Surgery), Roswell Park Comprehensive Cancer Center, Buffalo, New York, USA.
  • Abaza R; A.T.L.A.S. (Applied Technology Laboratory for Advanced Surgery), Roswell Park Comprehensive Cancer Center, Buffalo, New York, USA.
  • Guru KA; OhioHealth, Columbus, Ohio, USA.
  • Hussein AA; A.T.L.A.S. (Applied Technology Laboratory for Advanced Surgery), Roswell Park Comprehensive Cancer Center, Buffalo, New York, USA.
  • Eun D; A.T.L.A.S. (Applied Technology Laboratory for Advanced Surgery), Roswell Park Comprehensive Cancer Center, Buffalo, New York, USA.
J Endourol ; 36(5): 647-653, 2022 05.
Article in En | MEDLINE | ID: mdl-34809491
Objective: To develop a structured and objective scoring tool for assessment of robot-assisted partial nephrectomy (RAPN): Scoring for Partial Nephrectomy (SPaN). Materials and Methods:Content development: RAPN was deconstructed into 6 domains by a multi-institutional panel of 10 expert robotic surgeons. Performance on each domain was represented on a Likert scale of 1 to 5, with specific descriptions of anchors 1, 3, and 5. Content validation: The Delphi methodology was utilized to achieve consensus about the description of each anchor for each domain in terms of appropriateness of the skill assessed, objectiveness, clarity, and unambiguous wording. The content validity index (CVI) of ≥0.75 was set as cutoff for consensus. Reliability: 15 de-identified videos of RAPN were utilized to determine the inter-rater reliability using linearly weighted percent agreement, and Construct validation of SPaN was described in terms of median scores and odds ratios. Results: The expert panel reached consensus (CVI ≥0.75) after 2 rounds. Consensus was achieved for 36 (67%) statements in the first round and 18 (33%) after the second round. The final six-domain SPaN included Exposure of the kidney; Identification and dissection of the ureter and gonadal vessels; Dissection of the hilum; Tumor localization and exposure; Clamping and tumor resection; and Renorrhaphy. The linearly weighted percent agreement was >0.75 for all domains. There was no difference between median scores for any domain between attendings and trainees. Conclusion: Despite the lack of significant construct validity, SPaN is a structured, reliable, and procedure-specific tool that can objectively assesses technical proficiency for RAPN.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Robotics / Laparoscopy / Robotic Surgical Procedures / Kidney Neoplasms Type of study: Clinical_trials / Prognostic_studies Limits: Humans Language: En Journal: J Endourol Journal subject: UROLOGIA Year: 2022 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Robotics / Laparoscopy / Robotic Surgical Procedures / Kidney Neoplasms Type of study: Clinical_trials / Prognostic_studies Limits: Humans Language: En Journal: J Endourol Journal subject: UROLOGIA Year: 2022 Document type: Article Affiliation country: Country of publication: