Your browser doesn't support javascript.
loading
Digital PET vs Analog PET: Clinical Implications?
López-Mora, Diego Alfonso; Carrió, Ignasi; Flotats, Albert.
Affiliation
  • López-Mora DA; Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Barcelona, Spain. Electronic address: dlopezmo@santpau.cat.
  • Carrió I; Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Barcelona, Spain.
  • Flotats A; Nuclear Medicine Department, Hospital de la Santa Creu i Sant Pau, Universitat Autònoma de Barcelona, Barcelona, Spain.
Semin Nucl Med ; 52(3): 302-311, 2022 05.
Article in En | MEDLINE | ID: mdl-34836617
ABSTRACT
Positron emission tomography (PET) is a functional imaging technique introduced in 1970s. Over the years, PET was used alone but is in 2000 when the first hybrid PET/CT device was clinically introduced. Since then, PET has continuously been marked by technological developments, being the most recent one the introduction of silicon photomultipliers (SiPMs) as an alternative to standard photomultiplier tubes used in analog PET/CT systems. SiPMs, the basis for the so called digital PET/CT systems, are smaller than standard photomultiplier tubes (enabling higher spatial resolution) and provide up to 100% coverage of the crystal area, as well as high sensitivity, low noise, and fast timing resolution. SiPMs in combination with optimized acquisition and reconstruction parameters improve the localization of the annihilation events, provide high definition PET images, and offer higher sensitivity and higher diagnostic performance. This article summarizes the evidence about the superior performance of the state of the art digital PET and highlights its potential clinical implications. Digital PET opens new perspectives in the quantification and characterization of small lesions, which are mostly undetectable using analog PET systems, potentially changing patient management and improving outcomes in oncological and non-oncological diseases. Moreover, digital PET offers the possibility to reduce radiation dose and scan times which may facilitate the implementation of PET to address unmet clinical needs.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Positron-Emission Tomography / Positron Emission Tomography Computed Tomography Limits: Humans Language: En Journal: Semin Nucl Med Year: 2022 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Positron-Emission Tomography / Positron Emission Tomography Computed Tomography Limits: Humans Language: En Journal: Semin Nucl Med Year: 2022 Document type: Article