Your browser doesn't support javascript.
loading
Study on Motion Management of Pancreatic Cancer Treated by CyberKnife.
Jing, Shenghua; Jiang, Changchen; Ji, Xiaoqin; Qiu, Xiangnan; Li, Jing; Sun, Xiangdong; Zhu, Xixu.
Affiliation
  • Jing S; Department of Radiation Oncology, East Region Military Command General Hospital, Nanjing, China.
  • Jiang C; Department of Radiation Oncology, East Region Military Command General Hospital, Nanjing, China.
  • Ji X; Department of Radiation Oncology, East Region Military Command General Hospital, Nanjing, China.
  • Qiu X; Department of Radiation Oncology, East Region Military Command General Hospital, Nanjing, China.
  • Li J; Department of Radiation Oncology, East Region Military Command General Hospital, Nanjing, China.
  • Sun X; Department of Radiation Oncology, East Region Military Command General Hospital, Nanjing, China.
  • Zhu X; Department of Radiation Oncology, East Region Military Command General Hospital, Nanjing, China.
Front Oncol ; 11: 767832, 2021.
Article in En | MEDLINE | ID: mdl-34926273
PURPOSE: We investigated the movement characteristics of pancreas and the clinical accuracy of tracking pancreas with the Synchrony Respiratory Tracking System (SRTS) during the CyberKnife treatment. These data provide a clinical data basis for the expansion margins of pancreatic tumor target. METHODS AND MATERIALS: Forty-two patients with pancreatic cancer treated by CyberKnife were retrospectively studied. The pancreatic displacement calculated from the x-ray images collected during the time interval between two consecutive movements constituted a data set. RESULTS: The total mean motion amplitudes and standard deviations of pancreatic tumors in SI, LR, AP, and radial directions were 3.66 ± 1.71 mm, 0.97 ± 0.62 mm, 1.52 ± 1.02 mm, and 1.36 ± 0.49 mm, respectively. The overall mean correlation errors and standard deviations were 0.82 ± 0.46 mm, 0.47 ± 0.33 mm, 0.41 ± 0.24 mm, and 0.98 ± 0.37 mm, respectively. The overall mean prediction errors and standard deviations were 0.57 ± 0.14 mm, 0.62 ± 0.28 mm, 0.39 ± 0.17 mm, and 1.58 ± 0.36 mm, respectively. The correlation errors and prediction errors of pancreatic tumors at different anatomical positions in SI, LR, and AP directions were statistically significant (p < 0.05). CONCLUSIONS: The tumor motion amplitude, the tumor location, and the treatment time are the main factors affecting the tracking accuracy. The pancreatic tumors at different anatomical locations should be treated differently to ensure sufficient dose coverage of the pancreatic target area.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Front Oncol Year: 2021 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Prognostic_studies Language: En Journal: Front Oncol Year: 2021 Document type: Article Affiliation country: Country of publication: