Your browser doesn't support javascript.
loading
A Simple UPLC/MS-MS Method for Simultaneous Determination of Lenvatinib and Telmisartan in Rat Plasma, and Its Application to Pharmacokinetic Drug-Drug Interaction Study.
Cui, Yanjun; Li, Ying; Li, Xiao; Fan, Liju; He, Xueru; Fu, Yuhao; Dong, Zhanjun.
Affiliation
  • Cui Y; National Clinical Drug Monitoring Center, Department of Pharmacy, Hebei Province General Center, Shijiazhuang 050051, China.
  • Li Y; National Clinical Drug Monitoring Center, Department of Pharmacy, Hebei Province General Center, Shijiazhuang 050051, China.
  • Li X; Department of Pharmacy, Hebei General Hospital, Shijiazhuang 050051, China.
  • Fan L; National Clinical Drug Monitoring Center, Department of Pharmacy, Hebei Province General Center, Shijiazhuang 050051, China.
  • He X; Department of Pharmacy, Hebei General Hospital, Shijiazhuang 050051, China.
  • Fu Y; National Clinical Drug Monitoring Center, Department of Pharmacy, Hebei Province General Center, Shijiazhuang 050051, China.
  • Dong Z; National Clinical Drug Monitoring Center, Department of Pharmacy, Hebei Province General Center, Shijiazhuang 050051, China.
Molecules ; 27(4)2022 Feb 15.
Article in En | MEDLINE | ID: mdl-35209080
ABSTRACT
Lenvatinib is a multi-targeted tyrosine kinase inhibitor that inhibits tumor angiogenesis, but hypertension is the most common adverse reaction. Telmisartan is an angiotensin receptor blocker used to treat hypertension. In this study, a simple ultra-performance liquid chromatography-tandem mass spectrometry method was developed for the simultaneous determination of lenvatinib and telmisartan, and it was applied to the pharmacokinetic drug interaction study. Plasma samples were treated with acetonitrile to precipitate protein. Water (containing 5 mM of ammonium acetate and 0.1% formic acid) and acetonitrile (0.1% formic acid) were used as the mobile phases to separate the analytes with gradient elution using a column XSelect HSS T3 (2.1 mm × 100 mm, 2.5 µm). Multiple reaction monitoring in the positive ion mode was used for quantification. The method was validated and the precision, accuracy, matrix effect, recovery, and stability of this method were reasonable. The determination of analytes was not interfered with by other substances in the blank plasma, and the calibration curves of lenvatinib and telmisartan were linear within the range of 0.2-1000 ng/mL and 0.1-500 ng/mL, respectively. The results indicate that lenvatinib decreased the systemic exposure of telmisartan. Potential drug interactions were observed between lenvatinib and telmisartan.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Phenylurea Compounds / Quinolines / Chromatography, High Pressure Liquid / Drug Interactions / Tandem Mass Spectrometry / Telmisartan Type of study: Diagnostic_studies Limits: Animals Language: En Journal: Molecules Journal subject: BIOLOGIA Year: 2022 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Phenylurea Compounds / Quinolines / Chromatography, High Pressure Liquid / Drug Interactions / Tandem Mass Spectrometry / Telmisartan Type of study: Diagnostic_studies Limits: Animals Language: En Journal: Molecules Journal subject: BIOLOGIA Year: 2022 Document type: Article Affiliation country:
...