Customizable modification of banding with external stenting for arteriovenous fistula flow reduction.
J Vasc Surg Cases Innov Tech
; 8(2): 151-157, 2022 Jun.
Article
in En
| MEDLINE
| ID: mdl-35330904
We performed a single-center retrospective study of prospectively collected data for all patients who had flow reduction surgery with FRAME FR between November 2020 and January 2021. Ten patients had arteriovenous fistula flow reduction surgery with this technique. One patient had a distal fistula, whereas nine were within the cubital fossa. In nine patients the device was applied over the postanastomotic arteriovenous fistula outflow vein and in one in the preanastomotic radial artery. Technical success was achieved in all patients with a median flow reduction from 2150 to 825 mL/min. There were no wound or device-specific complications.
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Type of study:
Observational_studies
Language:
En
Journal:
J Vasc Surg Cases Innov Tech
Year:
2022
Document type:
Article
Affiliation country:
Country of publication: