Your browser doesn't support javascript.
loading
Novel field-portable high-pressure adsorbent tube sampler prototype for the direct in situ preconcentration of trace compounds in gases at their working pressures: application to biomethane.
Lecharlier, Aurore; Carrier, Hervé; Bouyssiere, Brice; Caumette, Guilhem; Chiquet, Pierre; Le Hécho, Isabelle.
Affiliation
  • Lecharlier A; Universite de Pau et des Pays de l'Adour, E2S UPPA, CNRS, TOTAL, LFCR UMR 5150 BP 1155 Avenue de l'Université 64013 Pau Cedex France.
  • Carrier H; Universite de Pau et des Pays de l'Adour, E2S UPPA, CNRS, IPREM UMR 5254 Technopôle Hélioparc, 2 Avenue du Président Angot 64053 Pau Cedex 09 France isabelle.lehecho@univ-pau.fr.
  • Bouyssiere B; Universite de Pau et des Pays de l'Adour, E2S UPPA, CNRS, TOTAL, LFCR UMR 5150 BP 1155 Avenue de l'Université 64013 Pau Cedex France.
  • Caumette G; Universite de Pau et des Pays de l'Adour, E2S UPPA, CNRS, IPREM UMR 5254 Technopôle Hélioparc, 2 Avenue du Président Angot 64053 Pau Cedex 09 France isabelle.lehecho@univ-pau.fr.
  • Chiquet P; Teréga 40 Avenue de l'Europe, CS 20 522 64010 Pau Cedex France.
  • Le Hécho I; Teréga 40 Avenue de l'Europe, CS 20 522 64010 Pau Cedex France.
RSC Adv ; 12(16): 10071-10087, 2022 Mar 25.
Article in En | MEDLINE | ID: mdl-35424932
In Europe, renewable energy gases such as biomethane are aimed at substituting natural gas provided their stringent compliance to natural gas quality standards stipulating maximal levels of several chemical trace compounds (TC). Preconcentration is generally required to detect TC and inasmuch as biomethane is compressed for injection in the natural gas grid, preconcentration is commonly either done by collecting the bulk pressurized gas in a high-pressure cylinder or by first depressurizing it to collect a bulk volume in e.g. a gas sampling bag. Such whole gas samples are then transported to the lab and transferred to a preconcentration unit, entailing contamination and TC loss risks. Therefore, here a novel handy field-portable device for the direct in situ high-pressure preconcentration of TC is presented, enabling to sample gases at pressures up to 200 bara through a self-assembled Tenax®TA + Carbopack™X multibed adsorbent tube. The effect of the gas sampling pressure on the preconcentration of TC on adsorbent tubes was evaluated using a synthetic gas mixture containing 41 halogenated volatile organic compounds each at 1 ppmmol in N2. At given normalized sampled volumes and in the pressure range 5-100 bara handled in French gas transport grids, the pressure had no influence on the preconcentration when the gas circulates through the adsorbent tubes and as long as the adsorbents are not saturated. Next, for the first time, a real biomethane stream was sampled using the novel direct high-pressure preconcentration method on Tenax®TA + Carbopack™X multibed adsorbent tubes, allowing to preconcentrate, in a single sampling run, a wide range of volatile organic TC. More than 26 distinct TC were detected, belonging to seven chemical families: alkenes, aromatics, alkanes (linear, cyclic and polycyclic), sulphur-compounds and terpenes, with linear alkanes (pentane, heptane, octane) and terpenes predominating. Semi-quantification indicated pentane, dimethylcyclopropane, hexane, heptane, octane, α-pinene and camphene are present at a ≤1 ppmmol concentration threshold in the biomethane.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: RSC Adv Year: 2022 Document type: Article Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: RSC Adv Year: 2022 Document type: Article Country of publication: