Your browser doesn't support javascript.
loading
Initial Experience with Left Bundle Branch Area Pacing with Conventional Stylet-Driven Extendable Screw-In Leads and New Pre-Shaped Delivery Sheaths.
Byeon, Kyeongmin; Kim, Hye Ree; Park, Seung-Jung; Park, Young Jun; Choi, Ji-Hoon; Kim, Ju Youn; Park, Kyoung-Min; On, Young Keun; Kim, June Soo.
Affiliation
  • Byeon K; Division of Cardiology, Department of Internal Medicine, Chung-Ang University Gwangmyeong Hospital, Chung-Ang University College of Medicine, Gwangmyeong 14353, Korea.
  • Kim HR; Division of Cardiology, Department of Internal Medicine, Gyeongsang National University Hospital, Gyeongsang National University School of Medicine, Jinju 52727, Korea.
  • Park SJ; Division of Cardiology, Department of Internal Medicine, Heart Vascular and Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea.
  • Park YJ; Division of Cardiology, Department of Internal Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju 26426, Korea.
  • Choi JH; Division of Cardiology, Department of Internal Medicine, Heart Vascular and Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea.
  • Kim JY; Division of Cardiology, Department of Internal Medicine, Heart Vascular and Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea.
  • Park KM; Division of Cardiology, Department of Internal Medicine, Heart Vascular and Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea.
  • On YK; Division of Cardiology, Department of Internal Medicine, Heart Vascular and Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea.
  • Kim JS; Division of Cardiology, Department of Internal Medicine, Heart Vascular and Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 06351, Korea.
J Clin Med ; 11(9)2022 Apr 28.
Article in En | MEDLINE | ID: mdl-35566608
ABSTRACT
Until recently, left bundle branch area pacing (LBBAp) has mostly been performed using lumen-less fixed screw leads. There are limited data on LBBAp with conventional style-driven extendable screw-in (SDES) leads, particularly data performed by operators with no previous experience with LBBAp procedures. In total, 42 consecutive patients undergoing LBBAp using SDES leads and newly designed delivery sheaths (LBBAp group) were compared with those treated with conventional right ventricular pacing (RVp) for atrioventricular block (RVp group, n = 84) using propensity score matching (12 ratio). The LBBAp was successful in 83% (35/42) of patients, with satisfactory pacing thresholds (0.8 ± 0.2 V at 0.4 ms). In the LBBAp group, the mean paced-QRS duration obtained during RV apical pacing (173 ± 18 ms) was significantly reduced by LBBAp (116 ± 14 ms, p < 0.001). Compared with the RVp group, the LBBAp group showed more physiological pacing, suggested by a much narrower paced-QRS duration (116 ± 14 vs. 151 ± 21 ms, p < 0.001). The pacing threshold was comparable in both groups. The LBBAp group revealed stable pacing thresholds for 6.8 ± 4.8 months post-implant and no serious complications including lead dislodgement or septal perforation. The novel approach of LBBAp using SDES leads and the new dedicated pre-shaped delivery sheaths was effectively and safely performed, even by inexperienced operators with LBBAp procedures.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Clin Med Year: 2022 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Clin Med Year: 2022 Document type: Article
...