Your browser doesn't support javascript.
loading
SARS-CoV-2 RNA Testing Using Different Assays-Impact on Testing Strategies in a Clinical Setting.
Eibinger, Gerald M; Kessler, Harald H; Stelzl, Evelyn; Vander, Klaus; Weber-Lassacher, Anita; Renner, Wilfried; Herrmann, Markus.
Affiliation
  • Eibinger GM; Clinical Institute of Medical and Chemical Laboratory Diagnostics, Medical University of Graz, 8036 Graz, Austria.
  • Kessler HH; Institute of Hygiene, Microbiology and Environmental Medicine, Medical University of Graz, 8036 Graz, Austria.
  • Stelzl E; Institute of Hygiene, Microbiology and Environmental Medicine, Medical University of Graz, 8036 Graz, Austria.
  • Vander K; Institute of Hospital Hygiene and Microbiology, University Hospital Graz, 8036 Graz, Austria.
  • Weber-Lassacher A; Institute of Hospital Hygiene and Microbiology, University Hospital Graz, 8036 Graz, Austria.
  • Renner W; Clinical Institute of Medical and Chemical Laboratory Diagnostics, Medical University of Graz, 8036 Graz, Austria.
  • Herrmann M; Clinical Institute of Medical and Chemical Laboratory Diagnostics, Medical University of Graz, 8036 Graz, Austria.
Int J Mol Sci ; 23(21)2022 Oct 25.
Article in En | MEDLINE | ID: mdl-36361632
In order to assess SARS-CoV-2 real time quantitative polymerase chain reaction (RT-qPCR) results in a real-life setting, three independent laboratories in Graz (Austria) set up a continuous cross comparison schedule. The following test systems were used: The QIAGEN NeuMoDx SARS-CoV-2 Assay, the Allplex™ 2019-nCoV Assay (Seegene) on a MicroLab Nimbus (Hamilton) platform combined with RealStar SARS-CoV-2 RT-PCR Assay (Altona Diagnostics GmbH), and the cobas SARS-CoV-2 test on a fully automated cobas 6800 system (Roche). A total of 200 samples were analysed, 184 (92%) were found to be concordant with all testing platforms, 14 (7%) discordant. Two (1%) samples tested invalid on a single platform and were excluded from further analysis. Discordant results were distributed randomly across the assays. The Ct values from all assays correlated closely with each other. All discordant samples showed Ct values ≥ 26. SARS-CoV-2 RT-qPCR assays may show considerable variability, especially in samples with low viral RNA concentrations. Decision makers should thus balance the advantages and disadvantages of RT-qPCR for mass screening and adopt suitable strategies that ensure a rational management of positive samples with high Ct values.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: SARS-CoV-2 / COVID-19 Type of study: Diagnostic_studies / Prognostic_studies / Screening_studies Limits: Humans Language: En Journal: Int J Mol Sci Year: 2022 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: SARS-CoV-2 / COVID-19 Type of study: Diagnostic_studies / Prognostic_studies / Screening_studies Limits: Humans Language: En Journal: Int J Mol Sci Year: 2022 Document type: Article Affiliation country: Country of publication: