Your browser doesn't support javascript.
loading
HPLC with Fluorescence and Photodiode Array Detection for Quantifying Capmatinib in Biological Samples: Application to In Vivo and In Vitro Studies.
Zayed, Aref; Jaber, Sana'a A; Al Hroot, Jomana; Hawamdeh, Sahar; Ayoub, Nehad M; Qinna, Nidal A.
Affiliation
  • Zayed A; Department of Medicinal Chemistry and Pharmacognosy, Faculty of Pharmacy, Jordan University of Science and Technology (JUST), Irbid 22110, Jordan.
  • Jaber SA; Department of Medicinal Chemistry and Pharmacognosy, Faculty of Pharmacy, Jordan University of Science and Technology (JUST), Irbid 22110, Jordan.
  • Al Hroot J; Department of Medicinal Chemistry and Pharmacognosy, Faculty of Pharmacy, Jordan University of Science and Technology (JUST), Irbid 22110, Jordan.
  • Hawamdeh S; Department of Medicinal Chemistry and Pharmacognosy, Faculty of Pharmacy, Jordan University of Science and Technology (JUST), Irbid 22110, Jordan.
  • Ayoub NM; Department of Clinical Pharmacy, Faculty of Pharmacy, Jordan University of Science and Technology (JUST), Irbid 22110, Jordan.
  • Qinna NA; University of Petra Pharmaceutical Center (UPPC), Faculty of Pharmacy and Medical Sciences, University of Petra, Amman 11196, Jordan.
Molecules ; 27(23)2022 Dec 05.
Article in En | MEDLINE | ID: mdl-36500674
Capmatinib, a recently approved tyrosine kinase inhibitor, is used for the treatment of non-small cell lung cancer. We describe two new HPLC methods for capmatinib quantification in vivo and in vitro. HPLC with a fluorescence detection method was used to quantify capmatinib in plasma for the first time. The method was successfully applied in a pharmacokinetic study following a 10 mg/kg oral dose of capmatinib given to rats. The chromatographic separation was performed using a Eurospher II 100-3 C18H (50 × 4 mm, 3 µm) column and a mobile phase containing 10 mM of ammonium acetate buffer (pH 5.5): acetonitrile (70:30, v/v), at a flow rate of 2.0 mL min-1. The study also describes the use of HPLC-PDA for the first time for the determination of capmatinib in human liver microsomes and describes its application to study its metabolic stability in vitro. Our results were in agreement with those reported using LC-MS/MS, demonstrating the reliability of the method. The study utilized a Gemini-NX C18 column and a mobile phase containing methanol: 20 mM ammonium formate buffer pH 3.5 (53:47, v/v), delivered at a flow rate of 1.1 mL min-1. These methods are suitable for supporting pharmacokinetic studies, particularly in bioanalytical labs lacking LC-MS/MS capabilities.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Carcinoma, Non-Small-Cell Lung / Lung Neoplasms Type of study: Diagnostic_studies Limits: Animals / Humans Language: En Journal: Molecules Journal subject: BIOLOGIA Year: 2022 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Carcinoma, Non-Small-Cell Lung / Lung Neoplasms Type of study: Diagnostic_studies Limits: Animals / Humans Language: En Journal: Molecules Journal subject: BIOLOGIA Year: 2022 Document type: Article Affiliation country: Country of publication: