Your browser doesn't support javascript.
loading
Polyethyleneimine-assisted co-deposition of polydopamine coating with enhanced stability and efficient secondary modification.
Li, Chun-Gong; Yang, Qinqin; Chen, Dong; Zhu, Hongliang; Chen, Jiachen; Liu, Runjin; Dang, Qi; Wang, Xiang.
Affiliation
  • Li CG; Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University Chongqing 400044 PR China qdangchn@cqu.edu.cn xwangchn@vip.sina.com.
  • Yang Q; Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University Chongqing 400044 PR China qdangchn@cqu.edu.cn xwangchn@vip.sina.com.
  • Chen D; Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University Chongqing 400044 PR China qdangchn@cqu.edu.cn xwangchn@vip.sina.com.
  • Zhu H; Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University Chongqing 400044 PR China qdangchn@cqu.edu.cn xwangchn@vip.sina.com.
  • Chen J; Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University Chongqing 400044 PR China qdangchn@cqu.edu.cn xwangchn@vip.sina.com.
  • Liu R; Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University Chongqing 400044 PR China qdangchn@cqu.edu.cn xwangchn@vip.sina.com.
  • Dang Q; Key Laboratory of Biorheological Science and Technology, Ministry of Education, College of Bioengineering, Chongqing University Chongqing 400044 PR China qdangchn@cqu.edu.cn xwangchn@vip.sina.com.
  • Wang X; Chongqing Engineering and Technology Research Center of Intelligent Rehabilitation and Eldercare, Chongqing City Management College Chongqing 401331 PR China.
RSC Adv ; 12(54): 34837-34849, 2022 Dec 06.
Article in En | MEDLINE | ID: mdl-36540211
ABSTRACT
The stability and grafting efficiency are important for polydopamine (pDA) coatings used as platforms for secondary grafting. In this work, polyethyleneimine (PEI) was co-deposited with dopamine on various materials (PP, PTFE and PVC), then immersed in a 1.0 M HCl solution or 1.0 M NaOH solution to investigate the detachment of the coatings using UV-vis spectroscopy, SEM, FTIR spectroscopy and XPS, and the effect of PEI molecular weight on the secondary grafting of heparin on the pDA/PEI coating was investigated through clotting time tests. The results showed that the detachment rates of the pDA/PEI coating (14.6%, 23.7%) co-deposited on PTFE in 1.0 M HCl or 1.0 M NaOH solutions were both lower than that of the pDA coating (35.0%, 74.6%), indicating that pDA/PEI coatings could better remain on substrates in a 1.0 M NaOH solution. Besides, pDA/PEI coatings on a PP membrane with both a higher deposition density and stability could be obtained when the mass ratio of DA/PEI was 2 1-1 1 and PEI molecular weight was 600 Da. After grafting heparin, it was found that the pDA/PEI coating with lower molecular weight (600 Da and 1800 Da) PEI could achieve a higher grafting density of heparin with a longer clotting time. Thus, the results provided better understanding about the stability of pDA/PEI coatings and efficiency of heparin grafting.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: RSC Adv Year: 2022 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: RSC Adv Year: 2022 Document type: Article
...