Your browser doesn't support javascript.
loading
A methodological study of 2D shear wave elastography for noninvasive quantitative assessment of renal fibrosis in patients with chronic kidney disease.
Lin, Yanjun; Chen, Jiaxin; Huang, Yongquan; Lin, Yuhong; Su, Zhongzhen.
Affiliation
  • Lin Y; Department of Ultrasound, Fifth Affiliated Hospital of Sun Yat-Sen University, Zhuhai, 519000, Guangdong Province, China.
  • Chen J; Department of Ultrasound, Fifth Affiliated Hospital of Sun Yat-Sen University, Zhuhai, 519000, Guangdong Province, China.
  • Huang Y; Department of Ultrasound, Fifth Affiliated Hospital of Sun Yat-Sen University, Zhuhai, 519000, Guangdong Province, China.
  • Lin Y; Department of Ultrasound, Fifth Affiliated Hospital of Sun Yat-Sen University, Zhuhai, 519000, Guangdong Province, China. zslyh@126.com.
  • Su Z; Department of Ultrasound, Fifth Affiliated Hospital of Sun Yat-Sen University, Zhuhai, 519000, Guangdong Province, China. sp9313@126.com.
Abdom Radiol (NY) ; 48(3): 987-998, 2023 03.
Article in En | MEDLINE | ID: mdl-36565332
ABSTRACT

PURPOSE:

To determine the optimal measurement method of 2D shear wave elastography (2D-SWE) for noninvasive quantitative assessment of renal fibrosis in chronic kidney disease (CKD) patients.

METHODS:

A total of 190 CKD patients were enrolled for 2D-SWE of right kidney. The success rates, coefficients of variation (CV), and pathological correlation of different measurement sites, body positions, and depths were compared.

RESULTS:

(1) Measurement sites Success rate in the middle part (100%) was higher than that in the lower pole (97.3%, P > 0.05). CV in the middle part (10.2%) was lower than that in the lower pole (16.4%, P < 0.05). Pathological correlation of the middle part (r = - 0.452, P < 0.05) was higher than that of the lower pole (r = 0.097, P > 0.05). (2) Body positions Success rate in left lateral decubitus position (100%) was higher than that in supine (99.4%, P > 0.05) and prone position (99.4%, P > 0.05). CV was lowest (11.9%) and pathological correlation was highest (r = -0.256, P < 0.05) in prone position. (3) Measurement depths Success rate at depth < 4 cm (100%) was higher than that at depth ≥ 4 cm (98.8%, P > 0.05). CV at depth < 4 cm (11.1%) was lower than that at depth ≥ 4 cm (14.4%, P < 0.05). Pathological correlation at depth < 4 cm (r = - 0.303, P < 0.05) was higher than that at depth ≥ 4 cm (r = - 0.156, P > 0.05).

CONCLUSION:

The optimal measurement method of 2D-SWE for renal fibrosis assessment was prone position, renal middle part, and measurement depth < 4 cm.