Corneal biomechanical characteristics following small incision lenticule extraction for myopia and astigmatism with 3 different cap thicknesses.
Lv, Xiaotong; Zhang, Fengju; Song, Yanzheng; Zhai, Changbin; Guo, Ning; Lai, Lingbo; Xu, Yushan.
Affiliation
  • Lv X; Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Lab, No 1, Dongjiaominxiang Street, Dongcheng District, Beijing, 100730, China.
  • Zhang F; Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Lab, No 1, Dongjiaominxiang Street, Dongcheng District, Beijing, 100730, China. zhangfj126@126.com.
  • Song Y; Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Lab, No 1, Dongjiaominxiang Street, Dongcheng District, Beijing, 100730, China.
  • Zhai C; Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Lab, No 1, Dongjiaominxiang Street, Dongcheng District, Beijing, 100730, China.
  • Guo N; Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Lab, No 1, Dongjiaominxiang Street, Dongcheng District, Beijing, 100730, China.
  • Lai L; Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Lab, No 1, Dongjiaominxiang Street, Dongcheng District, Beijing, 100730, China.
  • Xu Y; Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Ophthalmology & Visual Sciences Key Lab, No 1, Dongjiaominxiang Street, Dongcheng District, Beijing, 100730, China.
BMC Ophthalmol ; 23(1): 42, 2023 Jan 30.
Article in En | MEDLINE | ID: mdl-36717828
BACKGROUND: The design of cap thickness for small incision lenticule extraction (SMILE) plays a role in post-laser vision correction (post-LVC) corneal biomechanics. This study aimed to compare the corneal biomechanical characteristics following SMILE with different cap thicknesses of 110 µm, 120 µm, and 130 µm for myopia and myopic astigmatism correction. METHODS: Seventy-five patients (146 eyes) who underwent SMILE with designed cap thickness of 110 µm, 120 µm, and 130 µm were recruited at the Eye Center of Beijing Tongren Hospital between August 2020 and November 2021. Visual acuity, refraction, and corneal biomechanical parameters were measured preoperatively, 1 week and 1, 3, 6 months postoperatively. One-way analysis of variances (ANOVA) with Bonferroni correction or Kruskal-Wallis test was performed to compare the parameters among different groups. Repeated-measures analysis of variance with Bonferroni correction or Friedman test was applied for comparing the parameters within different follow-up times. RESULTS: Uncorrected distance visual acuity of 110-µm group was better only at 1-week and 1-month postoperatively (P = 0.012, 0.037). There were no significant differences in spherical equivalent, nor in Corvis biomechanical index-laser vision correction (CBI-LVC). All the parameters reached stability at 3-month postoperatively. Integrated radius (IR) and deformation amplitude ratio 2 mm (DA ratio 2 mm) in 120-µm and 130-µm groups were higher than 110-µm group at 1-month postoperatively (P = 0.019, 0.002). So was Ambrósio relational thickness (ARTh) at 6-month postoperatively (P = 0.011). Stiffness parameter at applanation A1 (SP-A1), stress-strain index (SSI), biomechanically corrected intraocular pressure (bIOP) and central corneal thickness (CCT) were highest in 130-µm group, followed by 120-µm group, then 110-µm group at 3-month (P<0.001, P = 0.030, P = 0.027, P = 0.008) and 6-month (P<0.001, P = 0.002, P = 0.0023, P = 0.001) postoperatively. CONCLUSIONS: The corneal stiffness following SMILE was greatest with 130-µm cap, followed by 120-µm cap, then 110-µm cap. 130-µm cap might have advantages in terms of corneal biomechanics and retreatment option. The SMILE-designed protocol should be customized in practice.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Astigmatism / Corneal Surgery, Laser / Myopia Type of study: Guideline Limits: Humans Language: En Journal: BMC Ophthalmol Journal subject: OFTALMOLOGIA Year: 2023 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Astigmatism / Corneal Surgery, Laser / Myopia Type of study: Guideline Limits: Humans Language: En Journal: BMC Ophthalmol Journal subject: OFTALMOLOGIA Year: 2023 Document type: Article Affiliation country: Country of publication: