Your browser doesn't support javascript.
loading
Conventional versus ultra-low dose computed tomogram in Crohn's disease: Do morphomics correlate with clinical data?
O'Mahony, A T; Waldron, M G; O'Shea, S; Mulryan, P; O'Connor, O J; Maher, M M.
Affiliation
  • O'Mahony AT; Department of Radiology, Cork University Hospital, Cork, T12DC4A, Ireland. Electronic address: alexlcoum@gmail.com.
  • Waldron MG; Department of Radiology, School of Medicine, Brookfield Health Complex, University College Cork, Cork, T12AK54, Ireland. Electronic address: mwaldron@ucc.ie.
  • O'Shea S; Department of Radiology, School of Medicine, Brookfield Health Complex, University College Cork, Cork, T12AK54, Ireland. Electronic address: 119434294@umail.ucc.ie.
  • Mulryan P; Department of Radiology, Cork University Hospital, Cork, T12DC4A, Ireland. Electronic address: p.mulryan@umail.ucc.ie.
  • O'Connor OJ; Department of Radiology, Cork University Hospital, Cork, T12DC4A, Ireland; Department of Radiology, School of Medicine, Brookfield Health Complex, University College Cork, Cork, T12AK54, Ireland. Electronic address: oj.oconnor@ucc.ie.
  • Maher MM; Department of Radiology, Cork University Hospital, Cork, T12DC4A, Ireland; Department of Radiology, School of Medicine, Brookfield Health Complex, University College Cork, Cork, T12AK54, Ireland. Electronic address: m.maher@ucc.ie.
Radiography (Lond) ; 29(4): 712-720, 2023 07.
Article in En | MEDLINE | ID: mdl-37196480
ABSTRACT

BACKGROUND:

Cross-sectional study to assess the body composition of patients with Crohn's disease (CD) on standard (SDCT) and low dose CT (LDCT) protocols for the abdomen and pelvis (CTAP). We aimed to assess if a low dose CT protocol reconstructed with model-based iterative reconstruction (IR) could evaluate body morphometric data comparable to standard dose examination.

METHODS:

The CTAP images of 49 patients who underwent a low dose CT scan (20% of standard dose) and a second at standard dose minus 20% were assessed retrospectively. Images were collected from the PACS system, deidentified and analysed using a web-based semi-automated threshold-based segmentation tool (CoreSlicer), capable of identifying tissue type based on differences in attenuation co-efficient. The cross-sectional area (CSA) and Hounsfield units (HU) of each tissue was recorded.

RESULTS:

Muscle and fat CSA is well preserved on comparing these derived metrics from low dose and standard dose CT scans of abdomen and pelvic in CD ((LDCTSDCT mean CSA (cm2); Psoas muscle - 29.0028.67, total lumbar muscle - 127.45125.55, visceral fat- 110.44114.16, subcutaneous fat - 250.88255.05)). A fixed difference exists when assessing the attenuation of muscle, with higher attenuation on the low dose protocol (LDCTSDCT mean attenuation (HU); Psoas muscle - 61.6752.25, total lumbar muscle - 49.2941.20).

CONCLUSION:

We found comparable CSA across all tissues (muscle and fat) on both protocols with a strong positive correlation. A marginally lower muscle attenuation suggestive of less dense muscle was highlighted on SDCT. This study augments previous studies suggesting that comparable and reliable morphomic data may be generated from low dose and standard dose CT images. IMPLICATIONS FOR PRACTICE Threshold-based segmental tools can be used to quantify body morphomics on standard and low dose computed tomogram protocols.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Crohn Disease Type of study: Guideline / Observational_studies / Prevalence_studies / Risk_factors_studies Limits: Humans Language: En Journal: Radiography (Lond) Year: 2023 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Crohn Disease Type of study: Guideline / Observational_studies / Prevalence_studies / Risk_factors_studies Limits: Humans Language: En Journal: Radiography (Lond) Year: 2023 Document type: Article
...