Your browser doesn't support javascript.
loading
Comparison of transcatheter leaflet-approximation and direct annuloplasty in tricuspid regurgitation.
Ochs, Laurin; Körber, Maria Isabel; Wienemann, Hendrik; Tichelbäcker, Tobias; Iliadis, Christos; Metze, Clemens; Brüwer, Monique; Schmidt, Tobias; Omran, Hazem; Fortmeier, Vera; Friedrich, Kai; Rudolph, Volker; Baldus, Stephan; Pfister, Roman.
Affiliation
  • Ochs L; Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany. Laurin.Ochs@uk-koeln.de.
  • Körber MI; Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany.
  • Wienemann H; Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany.
  • Tichelbäcker T; Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany.
  • Iliadis C; Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany.
  • Metze C; Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany.
  • Brüwer M; Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany.
  • Schmidt T; Medical Clinic II, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany.
  • Omran H; DZHK (German Center for Cardiovascular Research), Partner Site Hamburg/Kiel/Lübeck, Lübeck, Germany.
  • Fortmeier V; Department of General and Interventional Cardiology, Heart and Diabetes Center Northrhine-Westfalia, Ruhr University Bochum, Bad Oeynhausen, Germany.
  • Friedrich K; Department of General and Interventional Cardiology, Heart and Diabetes Center Northrhine-Westfalia, Ruhr University Bochum, Bad Oeynhausen, Germany.
  • Rudolph V; Department of General and Interventional Cardiology, Heart and Diabetes Center Northrhine-Westfalia, Ruhr University Bochum, Bad Oeynhausen, Germany.
  • Baldus S; Department of General and Interventional Cardiology, Heart and Diabetes Center Northrhine-Westfalia, Ruhr University Bochum, Bad Oeynhausen, Germany.
  • Pfister R; Faculty of Medicine and University Hospital Cologne, Clinic III for Internal Medicine, University of Cologne, Kerpener Straße 62, 50937, Cologne, Germany.
Clin Res Cardiol ; 113(1): 126-137, 2024 Jan.
Article in En | MEDLINE | ID: mdl-37642720
BACKGROUND: Transcatheter repair emerges as a treatment option in patients with tricuspid regurgitation (TR) and high surgical risk. AIMS: This study aimed to compare leaflet-based and annuloplasty-based transcatheter repair in patients with TR. METHODS: In a retrospective analysis consecutive patients undergoing either transcatheter edge-to-edge repair (TEER) or direct annuloplasty (AP) for relevant TR at 2 centers were compared with respect to baseline characteristics, procedural efficacy and safety (death, myocardial infarction, procedure or device-related cardiothoracic surgery, or stroke at 30 days). RESULTS: 161 patients (57% female, median age 79 [75-82] years) with comparable clinical baseline characteristics in the TEER (n = 87) and AP (n = 74) group were examined. Baseline TR grade was significantly less severe in the TEER compared to the AP group (torrential 9.2 vs. 31.1%, p = 0.001). Technical success and improvement of TR grades were not significantly different across groups. In analysis matched for baseline TR severity, reduction of TR grade to less than moderate was significantly more common in the AP group (47.8 vs. 26.1%, p = 0.031). Major or more severe bleeding occurred in 9.2% of TEER and 20.3% of AP patients (p = 0.049) without any fatal bleedings. Major adverse events (MAE) were similar across groups with four patients (4.7%) in the TEER group and five patients (6.9%) in the AP group (p = 0.733) and 6-month survival did not differ significantly. CONCLUSIONS: Differences observed between patients treated with TEER and AP provide first evidence for tailoring distinct transcatheter treatment techniques to individual patient characteristics.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tricuspid Valve Insufficiency / Heart Valve Prosthesis Implantation Limits: Aged / Female / Humans / Male Language: En Journal: Clin Res Cardiol Journal subject: CARDIOLOGIA Year: 2024 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Tricuspid Valve Insufficiency / Heart Valve Prosthesis Implantation Limits: Aged / Female / Humans / Male Language: En Journal: Clin Res Cardiol Journal subject: CARDIOLOGIA Year: 2024 Document type: Article Affiliation country: Country of publication: