A modified prosthesis eversion technique for proximal anastomosis in ascending aorta replacement.
Zheng, Hua-Jie; Zhang, Xian-Pu; Yu, San-Jiu; Lin, De-Qing; Cheng, Yong-Bo; Yan, Chao-Jun; He, Ping; Li, Jun; Cheng, Wei.
Affiliation
  • Zheng HJ; Department of Cardiac Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China.
  • Zhang XP; Department of Cardiac Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China.
  • Yu SJ; Department of Cardiac Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China.
  • Lin DQ; Department of Cardiac Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China.
  • Cheng YB; Department of Cardiac Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China.
  • Yan CJ; Department of Cardiac Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China.
  • He P; Department of Cardiac Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China.
  • Li J; Department of Cardiac Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China.
  • Cheng W; Department of Cardiac Surgery, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China.
J Thorac Dis ; 15(9): 4596-4605, 2023 Sep 28.
Article in En | MEDLINE | ID: mdl-37868872
ABSTRACT

Background:

One of the crucial aspects of ascending aorta replacement is to achieve hemostasis of the proximal anastomosis. This study aimed to describe a modified prosthesis eversion technique for proximal anastomosis in ascending aorta replacement and compare its operative outcomes with the conventional prosthesis eversion technique.

Methods:

We conducted a retrospective analysis of all consecutive patients who had ascending aortic aneurysm and underwent ascending aorta replacement with the modified or conventional prosthesis eversion technique between January 2019 and December 2022 in our center.

Results:

A total of 108 patients were included 55 in the modified group and 53 in the conventional group. The durations of cardiopulmonary bypass, aortic cross-clamping and total operation in the conventional group were longer than those in the modified group. Furthermore, perioperative blood loss and the incidence of re-exploration for bleeding were significantly lower in the modified group. Accordingly, patients in the conventional group accepted more blood transfusion. The modified group had a shorter duration in intensive care unit (ICU) and hospital, and lower total hospitalization costs than those in the conventional group.

Conclusions:

The modified prosthesis eversion technique is an effective alternative for proximal anastomosis in ascending aorta replacement, with less blood loss, shorter operation time, and lower rate of postoperative complications compared with the conventional technique.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: J Thorac Dis Year: 2023 Document type: Article Affiliation country: