SEEG electrode shaft affects amplitude and latency of potentials evoked with single pulse electrical stimulation.
J Neurosci Methods
; 403: 110035, 2024 03.
Article
in En
| MEDLINE
| ID: mdl-38128785
ABSTRACT
BACKGROUND:
Long and thin shaft electrodes are implanted intracerebrally for stereoelectroencephalography (SEEG) in patients with pharmacoresistant focal epilepsies. Two adjacent contacts of one of such electrodes can deliver a train of single pulse electrical stimulations (SPES), and evoked potentials (EPs) are recorded on other contacts. In this study we assess if stimulating and recording on the same shaft, as opposed to different shafts, has an impact on common EP features. NEWMETHOD:
We leverage the large volume of SEEG data gathered in the F-TRACT database and analyze data from nearly one thousand SEEG implantations in order to verify whether stimulation and recording from the same shaft influence the EP pattern.RESULTS:
We found that when the stimulated and the recording contacts were located on the same shaft, the mean and median amplitudes of an EP are greater, and its mean and median latencies are smaller than when the contacts were located on different shafts. This effect is small (Cohen's d â¼ 0.1), but robust (p-value < 10-3) across the SEEG database. COMPARISON WITH EXISTING METHOD(S) Our study is the first one to address this question. Due to the choice of commonly used EP features, our method is congruent with other studies.CONCLUSIONS:
The magnitude of the reported effect does not obligate all standard analyses to correct for it, unless they aim at high precision. The source of the effect is not clear. Manufacturers of SEEG electrodes could examine it and potentially minimize the effect in their future products.Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Stereotaxic Techniques
/
Epilepsies, Partial
Limits:
Humans
Language:
En
Journal:
J Neurosci Methods
Year:
2024
Document type:
Article
Country of publication: