Classification of diabetic maculopathy based on optical coherence tomography images using a Vision Transformer model.
Cai, Liwei; Wen, Chi; Jiang, Jingwen; Liang, Congbi; Zheng, Hongmei; Su, Yu; Chen, Changzheng.
Affiliation
  • Cai L; Department of Ophthalmology, Renmin Hospital of Wuhan University, Wuhan, Hubei, China.
  • Wen C; Wuhan University School of Computer Science, Wuhan, Hubei, China.
  • Jiang J; State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, Guangdong, China.
  • Liang C; Department of Ophthalmology, Renmin Hospital of Wuhan University, Wuhan, Hubei, China.
  • Zheng H; Department of Ophthalmology, Renmin Hospital of Wuhan University, Wuhan, Hubei, China.
  • Su Y; Department of Ophthalmology, Renmin Hospital of Wuhan University, Wuhan, Hubei, China whuchenchzh@163.com sy_daisy1206@163.com.
  • Chen C; Department of Ophthalmology, Renmin Hospital of Wuhan University, Wuhan, Hubei, China whuchenchzh@163.com sy_daisy1206@163.com.
BMJ Open Ophthalmol ; 8(1)2023 12 21.
Article in En | MEDLINE | ID: mdl-38135350
ABSTRACT

PURPOSE:

To develop a Vision Transformer model to detect different stages of diabetic maculopathy (DM) based on optical coherence tomography (OCT) images.

METHODS:

After removing images with poor quality, a total of 3319 OCT images were extracted from the Eye Center of the Renmin Hospital of Wuhan University and randomly split the images into training and validation sets in a 73 ratio. All macular cross-sectional scan OCT images were collected retrospectively from the eyes of DM patients from 2016 to 2022. One of the OCT stages of DM, including early diabetic macular oedema (DME), advanced DME, severe DME and atrophic maculopathy, was labelled on the collected images, respectively. A deep learning (DL) model based on Vision Transformer was trained to detect four OCT grading of DM.

RESULTS:

The model proposed in our paper can provide an impressive detection performance. We achieved an accuracy of 82.00%, an F1 score of 83.11%, an area under the receiver operating characteristic curve (AUC) of 0.96. The AUC for the detection of four OCT grading (ie, early DME, advanced DME, severe DME and atrophic maculopathy) was 0.96, 0.95, 0.87 and 0.98, respectively, with an accuracy of 90.87%, 89.96%, 94.42% and 95.13%, respectively, a precision of 88.46%, 80.31%, 89.42% and 87.74%, respectively, a sensitivity of 87.03%, 88.18%, 63.39% and 89.42%, respectively, a specificity of 93.02%, 90.72%, 98.40% and 96.66%, respectively and an F1 score of 87.74%, 84.06%, 88.18% and 88.57%, respectively.

CONCLUSION:

Our DL model based on Vision Transformer demonstrated a relatively high accuracy in the detection of OCT grading of DM, which can help with patients in a preliminary screening to identify groups with serious conditions. These patients need a further test for an accurate diagnosis, and a timely treatment to obtain a good visual prognosis. These results emphasised the potential of artificial intelligence in assisting clinicians in developing therapeutic strategies with DM in the future.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Retinal Diseases / Diabetes Mellitus / Diabetic Retinopathy / Macular Degeneration Limits: Humans Language: En Journal: BMJ Open Ophthalmol Year: 2023 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Retinal Diseases / Diabetes Mellitus / Diabetic Retinopathy / Macular Degeneration Limits: Humans Language: En Journal: BMJ Open Ophthalmol Year: 2023 Document type: Article Affiliation country: