Your browser doesn't support javascript.
loading
Comparison of intraocular lens tilt after capsular sutured scleral fixation with capsular segments versus uneventful cataract surgery.
Chang-Sotomayor, Meilin; Gϋell, José L; de Rojas Silva, Ma Victoria; Corretger, Xavier; Bandeira, Francisco; Mendez-Mourelle, Andrea; Veillet, Lorea Zurutuza; Adán, Alfredo; Figueras-Roca, Marc.
Affiliation
  • Chang-Sotomayor M; Department of Ophthalmology, Hospital Clinic de Barcelona (ICOF), Barcelona, Spain, 08028.
  • Gϋell JL; Instituto de Microcirugía Ocular (IMO), Cornea and Refractive Surgery unit, Barcelona, Spain, 08035.
  • de Rojas Silva MV; Department of Ophthalmology, Hospital Universitario de A Coruña, A Coruña, Spain, 15006.
  • Corretger X; Department of Ophthalmology, Hospital Clinic de Barcelona (ICOF), Barcelona, Spain, 08028.
  • Bandeira F; São Gonçalo Eye Hospital, Cornea and Refractive Surgery unit, Rio de Janeiro, Brasil, 8600-502.
  • Mendez-Mourelle A; Department of Ophthalmology, Hospital Clinic de Barcelona (ICOF), Barcelona, Spain, 08028.
  • Veillet LZ; Department of Ophthalmology, Hospital Universitario de A Coruña, A Coruña, Spain, 15006.
  • Adán A; Department of Ophthalmology, Hospital Clinic de Barcelona (ICOF), Barcelona, Spain, 08028.
  • Figueras-Roca M; Department of Ophthalmology, Hospital Clinic de Barcelona (ICOF), Barcelona, Spain, 08028.
Eur J Ophthalmol ; : 11206721231223997, 2024 Jan 05.
Article in En | MEDLINE | ID: mdl-38179681
ABSTRACT

PURPOSE:

To evaluate and compare intraocular lens (IOL) tilt between uneventful phacoemulsification with in-the-bag IOL implantation and sutured scleral fixation (SSF) of the lens bag with a capsular tension segment (type 6 D / Morcher) using a Sheimpflug camera.

SETTING:

Clinical Practice, Hospital. Barcelona and A Coruña, Spain.

DESIGN:

Retrospective, comparative multicenter study.

METHODS:

IOL tilt was compared between patients who underwent sutured scleral fixation with a capsular tension segment in a single eye (SSF group, n = 15) with patients who underwent uneventful IOL implantation (control group, n = 12) that were matched by biometric measurements. Post-operative refractive accuracy of biometric formulas by means of mean absolute error (MAE) was also reported. All patients underwent a general ophthalmic evaluation, anterior segment photography, and postoperative optical biometry (Zeiss IOLMaster® 500). In addition, IOL tilt was measured with a Scheimpflug camera (Pentacam R, Oculus Optikgerate Gmbh).

RESULTS:

Mean vertical tilt was similar in both groups (2.20+/-2.47° SSF vs 1.97 +/- 1.79° control; p = 0.836) but mean horizontal tilt tended to higher values in the SSF series (2.09 +/- 2.74° vs 0.94 +/- 1.17°; p = 0.139). Considering post-operative refractive error in diopters by MAE calculations, there was an underestimation of IOL power in the SSF group which was only statistically significant for Barrett Universal II (1.07 vs 0.32; p = 0.028) and Hill-RBF (0.95 vs 0.26; p = 0.024) formulas, but not for SRK/T (0.99 vs 0.42; p = 0.285) and Kane (0.96 vs 0.33; p = 0.083).

CONCLUSION:

Sutured scleral fixation of capsular tension segments in the presence of zonular instability does not seem to induce clinically significant IOL tilt compared to uneventful cataract extraction cases.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Clinical_trials Language: En Journal: Eur J Ophthalmol Journal subject: OFTALMOLOGIA Year: 2024 Document type: Article Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Clinical_trials Language: En Journal: Eur J Ophthalmol Journal subject: OFTALMOLOGIA Year: 2024 Document type: Article Country of publication: