Feasibility and Safety of Adopting a New Approach in Delivering a 450 nm Blue Laser with a Flattop Beam Profile in Vital Tooth Whitening. A Clinical Case Series with an 8-Month Follow-Up.
Hanna, Reem; Miron, Ioana Cristina; Benedicenti, Stefano.
Affiliation
  • Hanna R; Department of Surgical Sciences and Integrated Diagnostics, University of Genoa, 16132 Genoa, Italy.
  • Miron IC; Department of Restorative Dental Sciences, UCL-Eastman Dental Institute, Medical School, University College London, London WC1E 6DE, UK.
  • Benedicenti S; Department of Oral Surgery, King's College Hospital NHS Foundation Trust, Denmark Hill, London SE5 9RS, UK.
J Clin Med ; 13(2)2024 Jan 16.
Article in En | MEDLINE | ID: mdl-38256627
ABSTRACT
A prospective observational case series included six patients who presented with discoloured upper and lower teeth extending from the right second premolar to the left second premolar. The photoactivation dosimetry and treatment protocol were as follows λ 450 nm, 1 W, CW; flattop beam profile; 1 cm2; 15 J/spot; 10 irradiated spots; an irradiation time of 15 s/spot; three whitening cycles in a single session. Blanc One ULTRA+ was the bleaching agent. A visual analogue scale (VAS) was utilised to evaluate the pain intensity and dental hypersensitivity during treatment immediately after complete treatment (T1), 24 h (T2), and 8 h (T3) postoperatively, and at an 8-month follow-up timepoint (T4), whereas the dental colour shade change was assessed using the VITA colour shade guide pre-treatment (T0), T1, and T4. The Gingival index and modified Wong Baker faces scale were utilised to evaluate gingival inflammation and patients' treatment satisfaction, respectively. Our findings revealed a reduction in the dental colour shade of the six cases between 2 and 10- fold (average of 3.5-fold) at T1 and maintained at T4, indicating significant improvement in the colour shade change with optimal outcomes. The percentage of this improvement for all the patients was ranged between 16.6% and 33.3%. At all timepoints, a "0" score was provided for pain intensity, dental hypersensitivity, and gingival inflammation. Our study demonstrates the feasibility and safety of a λ 450 nm laser delivered with a flattop handpiece to achieve optimal whitening outcomes without adverse effects. This offers a useful guide for dental clinicians for vital in-office tooth whitening. Extensive clinical studies with large data are warranted to validate our study protocol.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Type of study: Guideline Language: En Journal: J Clin Med Year: 2024 Document type: Article Affiliation country: Country of publication: