Your browser doesn't support javascript.
loading
Covalent organic frame based high-performance nanocomposite for construction of ATP sensor.
Xi, Zhiyi; Xing, Juan; Yuan, Ruo; Yuan, Yali.
Affiliation
  • Xi Z; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, 400715, PR China.
  • Xing J; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, 400715, PR China.
  • Yuan R; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, 400715, PR China. Electronic address: yuanruo@swu.edu.cn.
  • Yuan Y; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing, 400715, PR China. Electronic address: y198688@swu.edu.cn.
Biosens Bioelectron ; 250: 116081, 2024 Apr 15.
Article in En | MEDLINE | ID: mdl-38316088
ABSTRACT
In this work, a novel covalent organic frame (TAPT-TFPB COF) with self-enhanced photoelectric activity was prepared for decorating on conductive single-walled carbon nanotubes (SWCNT) to synthetize a high-performance photoelectric nanocomposite (COF/SWCNT), in which the interfacial charge separation and photogenerated carrier migration rate was significantly improved to obtain desiring photoelectric conversion efficiency for generating an extremely high photocurrent. Accordingly, the synthetic COF/SWCNT was ingeniously applied in the fabrication of ultrasensitive photoelectrochemical (PEC) biosensor for realizing the trace ATP detection by integrating with an Exo III-assisted dual DNA recycling amplification strategy. The recycling amplification could efficiently convert trace target ATP into plentiful output DNA, which ingeniously triggered the hybridization chain reaction (HCR) to generate a long DNA strand with substantial quencher manganese porphyrin (MnPP) loading to depress the photocurrent of COF/SWCNT. The experimental data showed that proposed biosensor had a detection range from 10 fmol L-1 to 10 nmol L-1 with the detection limit as low as 2.75 fmol L-1 (S/N = 3). In addition, this proposed biosensor showed excellent analytical performance in terms of stability, specificity and reproducibility, providing a possibility to accomplish sensitive and accurate in vitro diagnosis.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biosensing Techniques / Nanotubes, Carbon / Nanocomposites Language: En Journal: Biosens Bioelectron Journal subject: BIOTECNOLOGIA Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Biosensing Techniques / Nanotubes, Carbon / Nanocomposites Language: En Journal: Biosens Bioelectron Journal subject: BIOTECNOLOGIA Year: 2024 Document type: Article