Your browser doesn't support javascript.
loading
Correlation between peri-implant bone mineral density and primary implant stability based on artificial intelligence classification.
Xiao, Yanjun; Lv, Lingfeng; Xu, Zonghe; Zhou, Lin; Lin, Yanjun; Lin, Yue; Guo, Jianbin; Chen, Jiang; Ou, Yanjing; Lin, Lin; Wu, Dong.
Affiliation
  • Xiao Y; School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350001, China.
  • Lv L; Fujian Provincial Engineering Research Center of Oral Biomaterial, Fujian Medical University, Fuzhou, 350001, China.
  • Xu Z; School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350001, China.
  • Zhou L; School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350001, China.
  • Lin Y; Fujian Provincial Engineering Research Center of Oral Biomaterial, Fujian Medical University, Fuzhou, 350001, China.
  • Lin Y; Newland Digital Technology Co., Ltd., Fuzhou, Fujian, China.
  • Guo J; Fujian Provincial Engineering Research Center of Oral Biomaterial, Fujian Medical University, Fuzhou, 350001, China.
  • Chen J; School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350001, China.
  • Ou Y; School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350001, China.
  • Lin L; Newland Digital Technology Co., Ltd., Fuzhou, Fujian, China.
  • Wu D; School and Hospital of Stomatology, Fujian Medical University, Fuzhou, 350001, China. wudong@fjmu.edu.cn.
Sci Rep ; 14(1): 3009, 2024 02 06.
Article in En | MEDLINE | ID: mdl-38321110
ABSTRACT
Currently, the classification of bone mineral density (BMD) in many research studies remains rather broad, often neglecting localized changes in BMD. This study aims to explore the correlation between peri-implant BMD and primary implant stability using a new artificial intelligence (AI)-based BMD grading system. 49 patients who received dental implant treatment at the Affiliated Hospital of Stomatology of Fujian Medical University were included. Recorded the implant stability quotient (ISQ) after implantation and the insertion torque value (ITV). A new AI-based BMD grading system was used to obtain the distribution of BMD in implant site, and the bone mineral density coefficients (BMDC) of the coronal, middle, apical, and total of the 1 mm site outside the implant were calculated by model overlap and image overlap technology. Our objective was to investigate the relationship between primary implant stability and BMDC values obtained from the new AI-based BMD grading system. There was a significant positive correlation between BMDC and ISQ value in the coronal, middle, and total of the implant (P < 0.05). However, there was no significant correlation between BMDC and ISQ values in the apical (P > 0.05). Furthermore, BMDC was notably higher at implant sites with greater ITV (P < 0.05). BMDC calculated from the new AI-based BMD grading system could more accurately present the BMD distribution in the intended implant site, thereby providing a dependable benchmark for predicting primary implant stability.
Subject(s)

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bone Density / Dental Implants Type of study: Prognostic_studies Limits: Humans Language: En Journal: Sci Rep Year: 2024 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Bone Density / Dental Implants Type of study: Prognostic_studies Limits: Humans Language: En Journal: Sci Rep Year: 2024 Document type: Article Affiliation country: