Your browser doesn't support javascript.
loading
Patient Satisfaction and Tear Film Break-Up Time After First-Time Wearing of Silicone Hydrogel Contact Lenses.
Misu, Naoko; Mimura, Tatsuya; Noma, Hidetaka; Shinbo, Koichiro.
Affiliation
  • Misu N; Ophthalmology, Teikyo University School of Medicine, Tokyo, JPN.
  • Mimura T; Ophthalmology, Teikyo University School of Medicine, Tokyo, JPN.
  • Noma H; Ophthalmology, Hachioji Medical Center, Tokyo Medical University, Hachioji, JPN.
  • Shinbo K; Ophthalmology, Nerima Station West Eye Clinic, Tokyo, JPN.
Cureus ; 16(1): e52516, 2024 Jan.
Article in En | MEDLINE | ID: mdl-38371096
ABSTRACT

PURPOSE:

The dryness and discomfort associated with soft contact lenses (SCLs) prevent their continued use. Recently, verofilcon A, a new daily disposable silicone hydrogel material SCL, was introduced, which has a high water content (surface water content of 80% or more) that overcomes the low water content drawback of silicone hydrogels. In this study, we evaluated the non-invasive tear break-up time (NIBUT) and comfort level in individuals wearing verofilcon A SCL for the first time.

METHODS:

We enrolled 42 first-time SCL wearers, comprising 84 eyes. NIBUT was measured using the DR-1α® dry eye observation device at the state of the naked eye before SCL wear (baseline) and at one and four weeks after the first SCL wear. Additionally, we conducted a questionnaire survey during the fourth week to assess the comfort level (0-10) of SCL wear.

Results:

 The NIBUT values were significantly higher at one week (10.8 ± 2.2 s, p<0.01) and four weeks (11.4 ± 2.2 s, p<0.01) after the first SCL wear than those at baseline (5.9 ± 2.0 s). Comfort level in SCL use was significantly higher at one week (9.0 ± 1.1, p<0.01) and four weeks (8.7 ± 1.2, p<0.01) than that at baseline (7.8 ± 1.8), and this level was higher regardless of the baseline NIBUT value.

CONCLUSION:

Prolonged BUT and increased comfort levels were observed in individuals wearing verofilcon A SCLs. Improvement in tear fluid retention was found to alleviate dry eye and discomfort, suggesting that verofilcon A may be a beneficial introductory lens for first-time SCL wearers.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Cureus Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Cureus Year: 2024 Document type: Article