ABSTRACT

BACKGROUND:

The platelet-driven contraction or retraction of blood clots has been utilized to obtain blood serum for laboratory studies, but now, in vitro clot contraction assays are used in research laboratories and clinics to assess platelet functionality. The static final extent of clot contraction measured using a clot size or expelled serum volume can be supplemented substantially with a dynamic analysis.

OBJECTIVES:

To provide a step-by-step protocol for a relatively simple and affordable new automated methodology to follow the kinetics of blood clot contraction, which allows for simultaneous measurements of various samples at a time and requires only a fluorescence plate reader.

METHODS:

The kinetics of clot contraction in whole blood was assessed by continuously detecting the fluorescence intensity of fluorescein isothiocyanate-albumin added to a blood sample before clotting and expelled into the serum during clot shrinkage.

RESULTS:

The clots are formed and fluorescence is measured in the wells of a black multiwell plate using a standard plate fluorescent reader. The specificity of this technique for clot contraction has been demonstrated by the strong inhibitory effects of blebbistatin, latrunculin A, and abciximab. To validate the new technique, increased fluorescence intensity in the contracting clots was measured in parallel with a visual decrease in clot size performed with the same blood samples.

CONCLUSION:

The resulting clot contraction dynamics based on the expulsion of fluorescein isothiocyanate-albumin can be quantified using a number of kinetic parameters as well as a phase kinetics analysis. The advantages and drawbacks of the new technique are discussed.