Your browser doesn't support javascript.
loading
Clinical observation of a modified technique for intrascleral fixation of flanged three-piece foldable intraocular lenses through a Hoffman pocket.
Ye, Hongfei; Wu, Mengxiao; Sun, Wan; Lyu, Jiao; Xu, Yu; Fei, Ping; Peng, Jie; Jin, Haiying; Zhao, Peiquan.
Affiliation
  • Ye H; Department of Ophthalmology, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
  • Wu M; Department of Ophthalmology, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
  • Sun W; Department of Ophthalmology, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
  • Lyu J; Department of Ophthalmology, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
  • Xu Y; Department of Ophthalmology, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
  • Fei P; Department of Ophthalmology, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
  • Peng J; Department of Ophthalmology, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
  • Jin H; Department of Ophthalmology, Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China.
  • Zhao P; Department of Ophthalmology, Xinhua Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
Front Med (Lausanne) ; 11: 1382100, 2024.
Article in En | MEDLINE | ID: mdl-38545507
ABSTRACT

Purpose:

To present the outcomes of a new technique for intrascleral fixation of a flanged three-piece foldable intraocular lens (IOL) without a conjunctival incision. Materials and

methods:

We retrospectively reviewed a consecutive series of 12 eyes of 12 patients who underwent scleral IOL fixation using this technique.

Results:

The follow-up period ranged 3-12 months. There was a significant improvement in best-corrected visual acuity, from 0.8 (1.6) logarithm of the minimum angle of resolution (logMAR) preoperatively to 0.45 (0.8) logMAR at the final postoperative follow-up (p = 0.012). Notable complications included one case of pupillary IOL capture and increased intraocular pressure.

Conclusion:

Our novel technique is a viable solution for managing secondary IOL fixation, enabling the use of a wider variety of IOLs and simplifying the reposition process for dislocated three-piece IOLs. This approach has the potential to lower complication rates and enhance patients' recovery.
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Front Med (Lausanne) Year: 2024 Document type: Article Affiliation country:

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: Front Med (Lausanne) Year: 2024 Document type: Article Affiliation country: