Your browser doesn't support javascript.
loading
De-aberration for transcranial photoacoustic computed tomography through an adult human skull.
ArXiv ; 2024 Apr 09.
Article in En | MEDLINE | ID: mdl-38659640
ABSTRACT
Noninvasive transcranial photoacoustic computed tomography (PACT) of the human brain, despite its clinical potential, remains impeded by the acoustic distortion induced by the human skull. The distortion, which is attributed to the markedly different material properties of the skull relative to soft tissue, results in heavily aberrated PACT images -- a problem that has remained unsolved in the past two decades. Herein, we report the first successful experimental demonstration of the de-aberration of PACT images through an ex-vivo adult human skull using a homogeneous elastic model for the skull. Using only the geometry, position, and orientation of the skull, we accurately de-aberrate the PACT images of light-absorbing phantoms acquired through an ex-vivo human skull, in terms of the recovered phantom features, for different levels of phantom complexity and positions. Our work addresses the longstanding challenge of skull-induced aberrations in transcranial PACT and advances the field towards unlocking the full potential of transcranial human brain PACT.

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: ArXiv Year: 2024 Document type: Article Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Language: En Journal: ArXiv Year: 2024 Document type: Article Country of publication: