Your browser doesn't support javascript.
loading
A sensitive immunosensor via Pd@Au0.85Pd0.15 in situ electrocatalysis generating H2O2 for quenching electrochemiluminescence of Ir(pbi)2(acac)@Ti3C2Tx MXene-PVA.
Ren, Xiang; Xie, Zuoxun; Li, Xiaojian; Wu, Dan; Wang, Huan; Li, Yuyang; Wang, Xueying; Zhao, Jinxiu; Wei, Qin.
Affiliation
  • Ren X; Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
  • Xie Z; Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
  • Li X; Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China; School of Chemistry and Chemical Engineering, Liaocheng University, Liaocheng, Shandong, 252000, PR China. Electronic address: lix
  • Wu D; Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
  • Wang H; Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
  • Li Y; Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
  • Wang X; Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
  • Zhao J; Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China; School of Materials Science and Engineering, University of Jinan, Jinan 250022, PR China. Electronic address: mse_zhaojx@ujn.edu.c
  • Wei Q; Key Laboratory of Chemical Sensing & Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China; Department of Chemistry, Sungkyunkwan University, Suwon, 16419, Republic of Korea. Electronic address: sdjndxwq@163.com.
Talanta ; 275: 126125, 2024 Aug 01.
Article in En | MEDLINE | ID: mdl-38663066
ABSTRACT
The establishment of rapid target analysis methods for cytokeratin fragment antigen 21-1 (CYFRA 21-1) is urgently needed. [Ir(pbi)2(acac)] (pbi = 2-(4-bromophenyl)-1-hydrogen -benzimidazole, acac = acetylacetonate) as traditional electrochemiluminescence (ECL) luminophores has been confined due to its non-negligible dark toxicity and poor water solubility leading to poor biocompatibility and electrical conductivity as an organic molecule. Hence, to overcome this limitation, [Ir(pbi)2(acac)] can be effectively loaded on the polyvinyl alcohol hydrogel modified Ti3C2Tx MXene surface (Ir@Ti3C2Tx-PVA) as sensing platform which can emit high ECL signals. Then, a quenching strategy was proposed to fabricate an ECL sandwich immunosensor using H2O2 as quencher molecules which can generated by Pd@Au0.85Pd0.15. Especially, the generation of O2 to H2O2 can be achieved through a two-electron (2e-) reaction pathway by Pd@Au0.85Pd0.15, to overcome the restriction that the H2O2 was virtually impossible to label or immobilize on the non-enzyme nanomaterials. The proposed ECL assay achieves a response to CYFRA 21-1 within the range of 0.1 pg/mL-100 ng/mL, with a detection limit of 8.9 fg/mL (S/N = 3). This work provided a feasible tactic to seek superior-performance ECL luminophore and quencher consequently set up a novel means to makeup ultrasensitive ECL biosensor, which extended the utilization potential of Ir(pbi)2(acac) in ECL assays.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Palladium / Polyvinyl Alcohol / Biosensing Techniques / Keratin-19 / Electrochemical Techniques / Gold / Hydrogen Peroxide / Luminescent Measurements Limits: Humans Language: En Journal: Talanta Year: 2024 Document type: Article

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Palladium / Polyvinyl Alcohol / Biosensing Techniques / Keratin-19 / Electrochemical Techniques / Gold / Hydrogen Peroxide / Luminescent Measurements Limits: Humans Language: En Journal: Talanta Year: 2024 Document type: Article