[Application of three-dimensional ultrasound technique in repairing dorsal foot wounds with medial sural artery perforator flaps].
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
; 38(5): 593-597, 2024 May 15.
Article
in Zh
| MEDLINE
| ID: mdl-38752247
ABSTRACT
Objective:
To investigate the accuracy of positioning perforator of medial sural artery with three-dimensional ultrasound technique guided by a wide band linear matrix array volume transducer probe before operation, and the effectiveness of the flap design based on this in repairing the dorsal foot wounds.Methods:
Between January 2019 and December 2022, 30 patients with skin and soft tissue defects of the dorsal foot were treated. There were 19 males and 11 females, with an average age of 43.9 years (range, 22-63 years). There were 12 cases of traffic accident injury, 15 cases of heavy crushing injury, and 3 cases of machine injury. The time from injury to hospitalization was 1-8 hours (mean, 3.5 hours). The wounds in size of 5 cm×3 cm to 17 cm×5 cm were thorough debrided and covered with vacuum sealing drainage dressing. Then the wounds were repaired with the medial sural artery perforator flaps after no obvious infection observed. To obtain the complete three-dimensional image, the number and position of the medial sural artery perforator branches and the position of the main blood vessels in the muscle were detected and recorded by wide band linear matrix array volume transducer probe before operation. Suitable perforating branches were selected to design the flap and guide the flap incision on this basis. The size of the perforating flap ranged from 6 cm×4 cm to 18 cm×6 cm. The sensitivity and positive predictive value were calculated by comparing preoperative exploration with intraoperative observation of perforating branches, so as to evaluate the positioning accuracy of three-dimensional ultrasound technique. The donor sites were sutured directly in 25 cases and repaired with free skin grafting in 5 cases.Results:
The 60 perforating branches of medial sural artery were found before operation and 58 during operation in 30 patients. Among them, pre- and intra-operative perforations were consistent with 56. The sensitivity was 93.3% and positive predictive value was 96.6%. The intramuscular position and route of the main blood vessels were basically consistent with the pre- and intra-operative observation. All flaps survived and wounds healed by first intention. All incisions at the donor sites healed by first intention, and all skin grafts survived. All patients were follow up 9-24 months (mean, 14.7 months). The appearance, color, and texture of the flaps were good, and no obvious effect on wearing shoes and walking. At last follow-up, the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hind score ranged from 80 to 92, with an average of 87.5. The patient satisfaction was excellent in 29 cases and good in 1 case.Conclusion:
The three-dimensional ultrasound technique guided by the wide band linear matrix array volume transducer probe can accurately locate the perforating branch of the medial sural artery, and the three-dimensional imaging is more intuitive, which can be used to guide the design and incision of the medial sural artery perforator flap.Key words
Full text:
1
Collection:
01-internacional
Database:
MEDLINE
Main subject:
Ultrasonography
/
Soft Tissue Injuries
/
Foot Injuries
/
Imaging, Three-Dimensional
/
Perforator Flap
Limits:
Adult
/
Female
/
Humans
/
Male
/
Middle aged
Language:
Zh
Journal:
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
Year:
2024
Document type:
Article
Country of publication: