Your browser doesn't support javascript.
loading
Benchmarking breath analysis using peppermint approach with gas chromatography ion mobility spectrometer coupled to micro thermal desorber.
Ruszkiewicz, Dorota M; Kiland, Kristian J; Mok, Yoonseo; Bartolomeu, Crista; Borden, Scott A; Thomas, Paul; Lam, Stephen; Myers, Renelle.
Affiliation
  • Ruszkiewicz DM; Integrative Oncology, BC Cancer Research Institute Vancouver, Vancouver, Canada.
  • Kiland KJ; University of British Columbia, Faculty of Medicine, Vancouver, British Columbia, Canada.
  • Mok Y; Integrative Oncology, BC Cancer Research Institute Vancouver, Vancouver, Canada.
  • Bartolomeu C; Integrative Oncology, BC Cancer Research Institute Vancouver, Vancouver, Canada.
  • Borden SA; Integrative Oncology, BC Cancer Research Institute Vancouver, Vancouver, Canada.
  • Thomas P; Integrative Oncology, BC Cancer Research Institute Vancouver, Vancouver, Canada.
  • Lam S; Centre for Analytical Science, Chemistry, School of Science, Loughborough University, Loughborough, United Kingdom.
  • Myers R; Integrative Oncology, BC Cancer Research Institute Vancouver, Vancouver, Canada.
J Breath Res ; 18(4)2024 Jul 04.
Article in En | MEDLINE | ID: mdl-38876091
ABSTRACT
The Peppermint Initiative, established within the International Association of Breath Research, introduced the peppermint protocol, a breath analysis benchmarking effort designed to address the lack of inter-comparability of outcomes across different breath sampling techniques and analytical platforms. Benchmarking with gas chromatography-ion mobility spectrometry (GC-IMS) using peppermint has been previously reported however, coupling micro-thermal desorption (µTD) to GC-IMS has not yet, been benchmarked for breath analysis. To benchmarkµTD-GC-IMS for breath analysis using the peppermint protocol. Ten healthy participants (4 males and 6 females, aged 20-73 years), were enrolled to give six breath samples into Nalophan bags via a modified peppermint protocol. Breath sampling after peppermint ingestion occurred over 6 h att= 60, 120, 200, 280, and 360 min. The breath samples (120 cm3) were pre-concentrated in theµTD before being transferred into the GC-IMS for detection. Data was processed using VOCal, including background subtractions, peak volume measurements, and room air assessment. During peppermint washout, eucalyptol showed the highest change in concentration levels, followed byα-pinene andß-pinene. The reproducibility of the technique for breath analysis was demonstrated by constructing logarithmic washout curves, with the average linearity coefficient ofR2= 0.99. The time to baseline (benchmark) value for the eucalyptol washout was 1111 min (95% CI 529-1693 min), obtained by extrapolating the average logarithmic washout curve. The study demonstrated thatµTD-GC-IMS is reproducible and suitable technique for breath analysis, with benchmark values for eucalyptol comparable to the gold standard GC-MS.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Breath Tests / Mentha piperita / Benchmarking Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: J Breath Res / Journal of breath research (Online) Year: 2024 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Breath Tests / Mentha piperita / Benchmarking Limits: Adult / Aged / Female / Humans / Male / Middle aged Language: En Journal: J Breath Res / Journal of breath research (Online) Year: 2024 Document type: Article Affiliation country: Country of publication: