Your browser doesn't support javascript.
loading
Cryogenic-zone-compression gas chromatography-mass spectrometry for the determination of 16 polycyclic aromatic hydrocarbons in extra virgin olive oil.
Arena, Alessia; Zoccali, Mariosimone; Tranchida, Peter Q; Mondello, Luigi.
Affiliation
  • Arena A; Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, former Veterinary School, University of Messina, Viale G. Palatucci snc, Messina 98168, Italy.
  • Zoccali M; Department of Mathematical and Computer Science, Physical Sciences and Earth Sciences, University of Messina, Viale F. Stagno d'Alcontres 31, Messina 98166, Italy. Electronic address: mzoccali@unime.it.
  • Tranchida PQ; Messina Institute of Technology c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, former Veterinary School, University of Messina, Viale G. Palatucci snc, Messina 98168, Italy.
  • Mondello L; Chromaleont s.r.l., c/o Department of Chemical, Biological, Pharmaceutical and Environmental Sciences, former Veterinary School, University of Messina, Viale G. Palatucci snc, Messina 98168, Italy; Messina Institute of Technology c/o Department of Chemical, Biological, Pharmaceutical and Environment
J Chromatogr A ; 1732: 465248, 2024 Sep 13.
Article in En | MEDLINE | ID: mdl-39128238
ABSTRACT
The present study is based on the development of a straightforward method for the determination (semi-quantification) of 16 polycyclic aromatic hydrocarbons (PAHs) in extra virgin olive oil (EVOO) using "cryogenic-zone-compression" (CZC) gas chromatography-single quadrupole mass spectrometry (GC-QMS). The use of CZC (through a loop-type cryogenic modulator) to achieve enhanced signal-to-noise ratios (s/n), enabled a simplification of the sample preparation step. In fact, a single extraction process (using only 500 µL of acetonitrile) was performed prior to injection. The CZC GC-QMS method aligns with the principles of green analytical chemistry, and enabled an average s/n increase of 14-fold compared to conventional GC-QMS. The method limits of quantification were in the 0.07-8.33 µg kg-1 range. Accuracy (at the 2 µg kg-1 and 10 µg kg-1 concentration levels) was in the 82-103 % range. Intra-day and inter-day precision (at 2 µg kg-1 and 10 µg kg-1 concentration levels) were in the 1.9-14.7 % and 5.9-9.1 % ranges, respectively, while the recovery values (at 10 µg kg-1) ranged from 24 % to 99 %. For all the PAHs investigated, a positive matrix effect was observed. Two PAHs were detected (in the selected-ion-monitoring mode) in six EVOOs among the ten samples (not more than one PAH per sample).
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polycyclic Aromatic Hydrocarbons / Olive Oil / Gas Chromatography-Mass Spectrometry Language: En Journal: J Chromatogr A Year: 2024 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Polycyclic Aromatic Hydrocarbons / Olive Oil / Gas Chromatography-Mass Spectrometry Language: En Journal: J Chromatogr A Year: 2024 Document type: Article Affiliation country: Country of publication: