Your browser doesn't support javascript.
loading
Cervical Sensorimotor Function Tests Using a VR Headset-An Evaluation of Concurrent Validity.
Forsberg, Karin; Jirlén, Johan; Jacobson, Inger; Röijezon, Ulrik.
Affiliation
  • Forsberg K; Department of Health, Education, and Technology, Luleå University of Technology, 97187 Luleå, Sweden.
  • Jirlén J; Department of Health, Education, and Technology, Luleå University of Technology, 97187 Luleå, Sweden.
  • Jacobson I; Department of Health, Education, and Technology, Luleå University of Technology, 97187 Luleå, Sweden.
  • Röijezon U; Department of Health, Education, and Technology, Luleå University of Technology, 97187 Luleå, Sweden.
Sensors (Basel) ; 24(17)2024 Sep 07.
Article in En | MEDLINE | ID: mdl-39275722
ABSTRACT
Sensorimotor disturbances such as disturbed cervical joint position sense (JPS) and reduced reaction time and velocity in fast cervical movements have been demonstrated in people with neck pain. While these sensorimotor functions have been assessed mainly in movement science laboratories, new sensor technology enables objective assessments in the clinic. The aim was to investigate concurrent validity of a VR-based JPS test and a new cervical reaction acuity (CRA) test. Twenty participants, thirteen asymptomatic and seven with neck pain, participated in this cross-sectional study. The JPS test, including outcome measures of absolute error (AE), constant error (CE), and variable error (VE), and the CRA test, including outcome measures of reaction time and maximum velocity, were performed using a VR headset and compared to a gold standard optical motion capture system. The mean bias (assessed with the Bland-Altman method) between VR and the gold standard system ranged from 0.0° to 2.4° for the JPS test variables. For the CRA test, reaction times demonstrated a mean bias of -19.9 milliseconds (ms), and maximum velocity a mean bias of -6.5 degrees per seconds (°/s). The intraclass correlation coefficients (ICCs) between VR and gold standard were good to excellent (ICC 0.835-0.998) for the JPS test, and excellent (ICC 0.931-0.954) for reaction time and maximum velocity for the CRA test. The results show acceptable concurrent validity for the VR technology for assessment of JPS and CRA. A slightly larger bias was observed in JPS left rotation which should be considered in future research.
Subject(s)
Key words

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Reaction Time / Neck Pain Limits: Adult / Female / Humans / Male / Middle aged Language: En Journal: Sensors (Basel) Year: 2024 Document type: Article Affiliation country: Country of publication:

Full text: 1 Collection: 01-internacional Database: MEDLINE Main subject: Reaction Time / Neck Pain Limits: Adult / Female / Humans / Male / Middle aged Language: En Journal: Sensors (Basel) Year: 2024 Document type: Article Affiliation country: Country of publication: