Your browser doesn't support javascript.
loading
Application Effect of A New Modified 3D PSI in Total Knee Arthroplasty for Knee Osteoarthritis / 昆明医科大学学报
Article in Zh | WPRIM | ID: wpr-1019075
Responsible library: WPRO
ABSTRACT
Objective To explore the application effect of new improved 3D printing individualized guidance(3D psi)in total knee arthroplasty(TKA)for knee osteoarthritis(KOA).Methods A total of 100 patients with KOA in 920th Hospital of Joint Logistics Support Force,PLA from January 2021 to January 2022 were selected,and were divided into 2 groups of 50 patients each using the randomized numerical table method.The control group was treated with conventional TKA,and the study group was treated with new improved 3D psi assisted TKA.The operation conditions,postoperative rehabilitation,complications,prosthesis component position deviation,knee range of motion(ROM),lower limb force line parameters[coronal distal femoral mechanical axis lateral angle(mldfa),lower limb mechanical axis angle(HKA)],gait parameters(percentage of support time,stride,pace),knee function(HSS score),quality of life(AIMS2 score)were observed.Results Com-pared with control group,the amount of intraoperative and postoperative blood loss and drainage volume 2 days after operation were less in the study group,and the operation time and hospital stay were shorter(P<0.05).The deviations of LTC Angle,FFC Angle,HKA Angle,LFC Angle and FTC Angle in the study group were smaller than those in the control group(P<0.05).At 3 months,6 months and 12 months after surgery,the percentage of knee ROM,supporting time,stride length and walking speed of the research group were higher than those of the control group,while the coronal-position mLDFA and HKA were lower than those of the control group(P<0.05).The proportion of WBC and PMN in joint fluid at 3 months,6 months and 12 months after surgery was lower than that in control group(P<0.05).The HSS score of the study group was higher than that of the control group at 3 months,6 months and 12 months after operation,and the AIMS2 score was lower than that of the control group(P<0.05).There was no statistically significant difference in the incidence of complications between the study group and the control group(P>0.05).Conclusion The new improved 3D PSI-assisted TKA treatment of KOA can optimize the surgical situation,improve operating accuracy,improve the patient's lower limb alignment,promote limb function recovery,help improve the quality of life,and has high safety.
Key words
Full text: 1 Database: WPRIM Language: Zh Journal: Journal of Kunming Medical University Year: 2024 Document type: Article
Full text: 1 Database: WPRIM Language: Zh Journal: Journal of Kunming Medical University Year: 2024 Document type: Article