Your browser doesn't support javascript.
loading
Determination of macrozamin in Rhizoma Heterosmilacis Japonicae by RP-HPLC / 中国中药杂志
Zhongguo Zhong Yao Za Zhi ; (24): 1900-1902, 2007.
Article in Zh | WPRIM | ID: wpr-307564
Responsible library: WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To develop a RP-HPLC method for the determination of the content of macrozamin in Rhizoma Heterosmilacis Japonicae.</p><p><b>METHOD</b>A Century C18 AQ column (4.6 mm x 250 mm, 5 microm) was used with the mobile phase consisted of water (4:96). The flow rate was 1.0 mL x min(-1). The detection wavelength was set at 215 nm, and the column temperature was 35 degrees C.</p><p><b>RESULT</b>The calibration curve was linear (r = 0.999 8) in the range of 19.12 - 382.4 microg x mL(-1) for macrozamin, the average recovery of the method was 99.5%, with RSD 2.1% (n = 9).</p><p><b>CONCLUSION</b>This method can be used for the quality study of Rhizoma Heterosmilacis Japonicae.</p>
Subject(s)
Full text: 1 Database: WPRIM Main subject: Plants, Medicinal / Chemistry / Reproducibility of Results / Chromatography, High Pressure Liquid / Methylazoxymethanol Acetate / Liliaceae / Rhizome / Methods Language: Zh Journal: Zhongguo Zhong Yao Za Zhi Year: 2007 Document type: Article
Full text: 1 Database: WPRIM Main subject: Plants, Medicinal / Chemistry / Reproducibility of Results / Chromatography, High Pressure Liquid / Methylazoxymethanol Acetate / Liliaceae / Rhizome / Methods Language: Zh Journal: Zhongguo Zhong Yao Za Zhi Year: 2007 Document type: Article